arrow
返回

3D DOSE VERIFICATION USING TOMOTHERAPY CT DETECTOR ARRAY

delete2012-02-01
delete18
PRE
AI
K
Ke Sheng *
R
Ryan Jones
W
Wensha Yang
S
Siddharth Saraiya
Q
Quan Chen
G
Geoff Sobering
G
G Olivera
P
Paul W. Read
DOI:10.1016/j.ijrobp.2010.12.043delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Purpose: To evaluate a three-dimensional dose verification method based on the exit dose using the onboard detector of tomotherapy. Methods and Materials: The study included 347 treatment fractions from 24 patients, including 10 prostate, 5 head and neck (HN), and 9 spinal stereotactic body radiation therapy (SBRT) cases. Detector sonograms were retrieved and back-projected to calculate entrance fluence, which was then forward-projected on the CT images to calculate the verification dose, which was compared with ion chamber and film measurement in the QA plans and with the planning dose in patient plans. Results: Root mean square (RMS) errors of 2.0%, 2.2%, and 2.0% were observed comparing the dose verification (DV) and the ion chamber measured point dose in the phantom plans for RN, prostate, and spinal SBRT patients, respectively. When cumulative dose in the entire treatment is considered, for HN patients, the error of the mean dose to the planning target volume (PTV) varied from 1.47% to 5.62% with a RMS error of 3.55%. For prostate patients, the error of the mean dose to the prostate target volume varied from -5.11% to 3.29%, with a RMS error of 2.49%. The RMS error of maximum doses to the bladder and the rectum were 2.34% (-4.17% to 2.61%) and 2.64% (-4.54% to 3.94%), respectively. For the nine spinal SBRT patients, the RMS error of the minimum dose to the PTV was 2.43% (-5.39% to 2.48%). The RMS error of maximum dose to the spinal cord was 1.05% (-2.86% to 0.89%). Conclusions: An excellent agreement was observed between the measurement and the verification dose. In the patient treatments, the agreement in doses to the majority of PTVs and organs at risk is within 5% for the cumulative treatment course doses. The dosimetric error strongly depends on the error in multileaf collimator leaf opening time with a sensitivity correlating to the gantry rotation period. (C) 2012 Elsevier Inc.
Keyword:
In vivo dosimetry
Exit dosimetry QA
Tomotherapy
Dose verification
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

I
International Journal of Radiation Oncology Biology Physics
IF:
6.5
论文数:
4.8W
被引数:
4.2W

机构

A
accuray inc.
学者数:
131
论文数: 78
被引数: 0
U
University of Virginia
学者数:
3.0W
论文数: 2.7W
被引数: 4.1W
引用论文

引用论文

On the accuracy and effectiveness of dose reconstruction for tomotherapy
err2001-03-01
err80
PREAI
errKapatoes, JM; Olivera, GH; Balog, JP; Keller, H; Reckwerdt, PJ; Mackie, TR
err分享
err收藏
Technical evaluation of radiation dose delivered in prostate cancer patients as measured by an implantable mosfet dosimeter通过植入式mosfet剂量计测量的前列腺癌患者辐射剂量的技术评估
err2007-11-01
err33
PREAI
errBeyer, Gloria P.; Scarantino, Charles W.; Prestidge, Bradley R.; Sadeghi, Amir G.; Anscher, Mitchell S.; Miften, Moyed; Carrea, Tammy B.; Sims, Marianne; Black, Robert D.
err分享
err收藏
3D Dosimetric verification of volumetric-modulated arc therapy by portal dosimetry
err2010-02-01
err170
PREAI
errMans, Anton; Remeijer, Peter; Olaciregui-Ruiz, Igor; Wendling, Markus; Sonke, Jan-Jakob; Mijnheer, Ben; van Herk, Marcel; Stroom, Joep C.
err分享
err收藏
A feasible method for clinical delivery verification and dose reconstruction in tomotherapy
err2001-04-09
err117
errOAAI
errKapatoes, JM; Olivera, GH; Ruchala, KJ; Smilowitz, JB; Reckwerdt, PJ; Mackie, TR
err分享
err收藏
Scatter correction for cone-beam CT in radiation therapy
err2009-05-18
err194
errOAAI
errZhu, Lei; Xie, Yaoqin; Wang, Jing; Xing, Lei
err分享
err收藏
TREATMENT PLANNING TO IMPROVE DELIVERY ACCURACY AND PATIENT THROUGHPUT IN HELICAL TOMOTHERAPY
err2009-07-01
err50
errOAAI
errWesterly, David C.; Soisson, Emilie; Chen, Quan; Woch, Katherine; Schubert, Leah; Olivera, Gustavo; Mackie, Thomas R.
err分享
err收藏
Characterization of scattered radiation in kV CBCT images using Monte Carlo simulations
err2006-10-24
err180
PREAI
errJarry, Genevieve; Graham, Sean A.; Moseley, Douglas J.; Jaffray, David J.; Siewerdsen, Jeffrey H.; Verhaegen, Frank
err分享
err收藏
学者 查看更多内容