返回
3D SR usimg with multi-freq phased array
DOI:10.1002/mp.16733.png)
摘要
En 中文
BackgroundHigh resolution imaging of the microvasculature plays an important role in both diagnostic and therapeutic applications in the brain. However, ultrasound pulse-echo sonography imaging the brain vasculatures has been limited to narrow acoustic windows and low frequencies due to the distortion of the skull bone, which sacrifices axial resolution since it is pulse length dependent.PurposeTo overcome the detect limit, a large aperture 256-module sparse hemispherical transmit/receive array was used to visualize the acoustic emissions of ultrasound-vaporized lipid-coated decafluorobutane nanodroplets flowing through tube phantoms and within rabbit cerebral vasculature in vivo via passive acoustic mapping and super resolution techniques.MethodsNanodroplets were vaporized with 55 kHz burst-mode ultrasound (burst length = 145 & mu;s, burst repetition frequency = 9-45 Hz, peak negative acoustic pressure = 0.10-0.22 MPa), which propagates through overlying tissues well without suffering from severe distortions. The resulting emissions were received at a higher frequency (612 or 1224 kHz subarray) to improve the resulting spatial resolution during passive beamforming. Normal resolution three-dimensional images were formed using a delay, sum, and integrate beamforming algorithm, and super-resolved images were extracted via Gaussian fitting of the estimated point-spread-function to the normal resolution data.ResultsWith super resolution techniques, the mean lateral (axial) full-width-at-half-maximum image intensity was 16 & PLUSMN; 3 (32 & PLUSMN; 6) & mu;m, and 7 & PLUSMN; 1 (15 & PLUSMN; 2) & mu;m corresponding to & SIM;1/67 of the normal resolution at 612 and 1224 kHz, respectively. The mean positional uncertainties were & SIM;1/350 (lateral) and & SIM;1/180 (axial) of the receive wavelength in water. In addition, a temporal correlation between nanodroplet vaporization and the transmit waveform shape was observed, which may provide the opportunity to enhance the signal-to-noise ratio in future studies.ConclusionsHere, we demonstrate the feasibility of vaporizing nanodroplets via low frequency ultrasound and simultaneously performing spatial mapping via passive beamforming at higher frequencies to improve the resulting spatial resolution of super resolution imaging techniques. This method may enable complete four-dimensional vascular mapping in organs where a hemispherical array could be positioned to surround the target, such as the brain, breast, or testicles.
Keyword:
focused ultrasound
nanodroplet
passive acoustic mapping
super resolution
期刊
IF:
3.2
论文数:
3.7W
被引数:
3.2W
机构
引用论文
Modifying the Seismic Source Array Spectrum to Reduce the Risk of Injury to Marine Mammals
Proceedings
IF0
Registration of human skull computed tomography data to an ultrasound treatment space using a sparse high frequency ultrasound hemispherical array
MEDICAL PHYSICS
IF3.2
Non-invasive transcranial volumetric ultrasound localization microscopy of the rat brain with continuous, high volume-rate acquisition连续,高体积率采集的大鼠脑的无创经颅体积超声定位显微镜
THERANOSTICS
IF13.3
In vivo whole brain microvascular imaging in mice using transcranial 3D Ultrasound Localization Microscopy使用经颅3D超声定位显微镜在小鼠体内进行全脑微血管成像
EBIOMEDICINE
IF10.8