Large aperture 4-D blood flow Doppler imaging with high temporal resolution remains an important challenge. Different from the conventional matrix-array strategy, we proposed a 4-D ultrasound vector Doppler (4D-UVD) imaging method using a $128+128$ row-column addressed (RCA) array and a 256-channel ultrasound platform. This method integrates ultrafast 2-D plane wave transmission sequence and least-squares multiangle Doppler velocity estimator. The accuracy of the proposed method was evaluated in both simulations and phantom experiments of parabolic flow. The simulated result shows that the root-mean-squared error (RMSE) of estimated velocity is less than 15%. In the phantom experiments, the relative mean bias $\overline {B}$ and the standard deviation (SD) $\overline {\sigma }$ of the velocity profiles are less than 7.9% and 6.9%, respectively, suggesting a high estimated precision. Furthermore, in vivo feasibility of the approach was demonstrated in the human carotid artery. The blood flow velocity of the carotid artery was continuously measured over seven cardiac cycles at a 1-kHz volume rate. The fluctuations of the estimated mean and peak velocities were highly consistent with the pulse waves measured using a gating pulse sensor, yielding synchronization coefficients of 0.85 and 0.87, respectively. It is thus concluded that the proposed method can achieve a large aperture 4-D vector flow imaging with high temporal resolution using an RCA probe.
Keyword:
Imaging
Doppler effect
Vectors
Estimation
Ultrasonic imaging
Three-dimensional displays
Focusing
Frequency control
Carotid arteries
Acoustics
4-D blood flow imaging
high volume rate ultrasound
row-column addressed (RCA) array
ultrasound vector Doppler (UVD)

期刊

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control 封面图
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
IF:
3.7
论文数:
6.7K
被引数:
1.4W

机构

F
fudan university
学者数:
11.8W
论文数: 7.7W
被引数: 121
引用论文

引用论文

Benign nodules in post-Fontan livers can show imaging features considered diagnostic for hepatocellular carcinoma
err2017-08-07
err0
PREAI
errMichael L. Wells; David M. Hough; Jeff L. Fidler; Patrick S. Kamath; Joseph T. Poterucha; Sudhakar K. Venkatesh
err分享
err收藏
Heat Transfer Coefficient Correlation for Convective Boiling Inside Plain and Microfin Tubes Using Genetic Algorithms
err2010-07-14
err0
PREAI
errMarco Antonio Silva Picanço; Júlio César Passos; Enio Pedone Bandarra Filho
err分享
err收藏
Competitive Repair by Naturally Dispersed Repetitive DNA during Non-Allelic Homologous Recombination
err2010-12-02
err0
errOAAI
errMargaret L. Hoang; Frederick J. Tan; David C. Lai; Sue E. Celniker; Roger A. Hoskins; Maitreya J. Dunham; Yixian Zheng; Douglas Koshland
err分享
err收藏
A single crystal row-column-array for 3D ultrasound imaging
err2024-04-01
err4
PREAI
errLi, Guo; Sun, Qiandong; Fu, Yapeng; Hou, Shilin; Zhang, Jiaming; Xu, K. L.; Dai, Y.
err分享
err收藏
Ultrafast Compound Doppler Imaging: Providing Full Blood Flow Characterization
err2011-01-01
err409
PREAI
errBercoff, Jeremy; Montaldo, Gabriel; Loupas, Thanasis; Savery, David; Meziere, Fabien; Fink, Mathias; Tanter, Mickael
err分享
err收藏
err分享
err收藏
学者 查看更多内容