We report on a micromachined silicon chip that is capable of providing a high-throughput functional assay based on calorimetry. A prototype twin microcalorimeter based on the Seebeck effect has been fabricated by using IC technology process steps in combination with micromachined postprocessing techniques. A biocompatible liquid rubber membrane supports two identical 0.5 x 2 cm(2) measurement chambers, situated at the cold and hot junction sites of a thermopile. The thermopile consists of 666 aluminum/p + -polysilicon thermocouples. The chambers can house up to 10(6) eukaryotic cells cultured to confiuence. The advantage of the device over microcalorimeters on the market, is the integration of the measurement channels on chip, rendering microvolume reaction vessels, ranging from 10 to 600 mu l, in the closest possible contact with the thermopile sensor (no springs are needed). Power and temperature sensitivity of the sensor are 23V/W and 130 mV/K, respectively. The small thermal inertia of the microchannels results in the short response time of 70 s, when filled with 50 mu l of water. Biological experiments were done with cultured kidney cells of Xenopus laevis (A6). The thermal equilibration time of the device is 45 minutes. Stimulation of transport mechanisms by reducing bath osmolality by 50% increased metabolism by 20%. Our results show that it is feasible to apply this large-area, small-volume whole-cell biosensor for drug discovery, where the binding assays that are commonly used to provide high-throughput need to be complemented with a functional assay. Solutions are brought onto the sensor by a simple pipette, making the use of an industrial microtiterplate dispenser feasible on a nx96-array of the microcalorimeter biosensor. Such an array of biosensors has been designed based on a new set of requirements as set forth by people in the field.
Keyword:
whole cell biosensor
physiometer
thermopile
sensor array
micromachining
high-throughput drug screening
cell metabolism
functional assay
microtiterplate
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Biomedical Microdevices 封面图
Biomedical Microdevices
IF:
3.3
论文数:
2.1K
被引数:
3.4K

机构

K
KU Leuven
学者数:
5.7W
论文数: 5.2W
被引数: 8.1W
I
interuniversity microelectronics centre
学者数:
6.3K
论文数: 3.9K
被引数: 0
引用论文

引用论文

暂无论文信息