arrow
返回

A Circular, Wireless Surface-Electromyography Array

delete2024-02-08
delete1
delete
OA
AI
K
Kenneth Deprez
E
E. Baecke
M
Mauranne Tijskens
R
Ruben Schoeters
M
Maarten Velghe
A
Arno Thielens *
DOI:10.3390/s24041119delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Commercial, high-tech upper limb prostheses offer a lot of functionality and are equipped with high-grade control mechanisms. However, they are relatively expensive and are not accessible to the majority of amputees. Therefore, more affordable, accessible, open-source, and 3D-printable alternatives are being developed. A commonly proposed approach to control these prostheses is to use bio-potentials generated by skeletal muscles, which can be measured using surface electromyography (sEMG). However, this control mechanism either lacks accuracy when a single sEMG sensor is used or involves the use of wires to connect to an array of multiple nodes, which hinders patients' movements. In order to mitigate these issues, we have developed a circular, wireless s-EMG array that is able to collect sEMG potentials on an array of electrodes that can be spread (not) uniformly around the circumference of a patient's arm. The modular sEMG system is combined with a Bluetooth Low Energy System on Chip, motion sensors, and a battery. We have benchmarked this system with a commercial, wired, state-of-the-art alternative and found an r = 0.98 (p < 0.01) Spearman correlation between the root-mean-squared (RMS) amplitude of sEMG measurements measured by both devices for the same set of 20 reference gestures, demonstrating that the system is accurate in measuring sEMG. Additionally, we have demonstrated that the RMS amplitudes of sEMG measurements between the different nodes within the array are uncorrelated, indicating that they contain independent information that can be used for higher accuracy in gesture recognition. We show this by training a random forest classifier that can distinguish between 6 gestures with an accuracy of 97%. This work is important for a large and growing group of amputees whose quality of life could be improved using this technology.
Keyword:
Surface-Electromyography
Bluetooth Low Energy
gesture recognition
Prosthetics
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Sensors 封面图
Sensors
IF:
3.5
论文数:
7.3W
被引数:
23.4W

机构

I
interuniversity microelectronics centre
学者数:
6.3K
论文数: 4.0K
被引数: 1.5K
引用论文

引用论文

Feature selection and dimensionality reduction: An extensive comparison in hand gesture classification by sEMG in eight channels armband approach
err2020-05-01
err56
PREAI
errMendes Junior, Jose Jair A.; Freitas, Melissa L. B.; Siqueira, Hugo, V; Lazzaretti, Andre E.; Pichorim, Sergio F.; Stevan Jr, Sergio L.
err分享
err收藏
Hollow Pt-Ni alloy nanospheres with tunable chamber structure and enhanced activity
err2011-01-01
err0
PREAI
errHui Li; Hong Lin; Ying Hu; Hexing Li; Ping Li; Xinggui Zhou
err分享
err收藏
Recent Advances in Cellular Glycomic Analyses
err2013-02-21
err0
errOAAI
errJun-ichi Furukawa; Naoki Fujitani; Yasuro Shinohara
err分享
err收藏
err分享
err收藏
Expression of Med19 in bladder cancer tissues and its role on bladder cancer cell growth
err2012-11-01
err0
PREAI
errHu Zhang; Haowen Jiang; Wei Wang; Jian Gong; Limin Zhang; Zhongqing Chen; Qiang Ding
err分享
err收藏
Lectin microarrays: concept, principle and applications
err2013-01-01
err0
PREAI
errJun Hirabayashi; Masao Yamada; Atsushi Kuno; Hiroaki Tateno
err分享
err收藏
err分享
err收藏
学者 查看更多内容