arrow
返回

A continuous arc delivery optimization algorithm for CyberKnife m6

delete2018-06-21
delete10
PRE
AI
V
Vasant Kearney *
M
Martina Descovich
A
Atchar Sudhyadhom
J
J Cheung
C
Christopher McGuinness
T
Timothy D. Solberg
DOI:10.1002/mp.13022delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
PurposeThis study aims to reduce the delivery time of CyberKnife m6 treatments by allowing for noncoplanar continuous arc delivery. To achieve this, a novel noncoplanar continuous arc delivery optimization algorithm was developed for the CyberKnife m6 treatment system (CyberArc-m6). Methods and MaterialsCyberArc-m6 uses a five-step overarching strategy, in which an initial set of beam geometries is determined, the robotic delivery path is calculated, direct aperture optimization is conducted, intermediate MLC configurations are extracted, and the final beam weights are computed for the continuous arc radiation source model. This algorithm was implemented on five prostate and three brain patients, previously planned using a conventional step-and-shoot CyberKnife m6 delivery technique. The dosimetric quality of the CyberArc-m6 plans was assessed using locally confined mutual information (LCMI), conformity index (CI), heterogeneity index (HI), and a variety of common clinical dosimetric objectives. ResultsUsing conservative optimization tuning parameters, CyberArc-m6 plans were able to achieve an average CI difference of 0.036 0.025, an average HI difference of 0.046 +/- 0.038, and an average LCMI of 0.920 +/- 0.030 compared with the original CyberKnife m6 plans. Including a 5 s per minute image alignment time and a 5-min setup time, conservative CyberArc-m6 plans achieved an average treatment delivery speed up of 1.545x +/- 0.305x compared with step-and-shoot plans. ConclusionsThe CyberArc-m6 algorithm was able to achieve dosimetrically similar plans compared to their step-and-shoot CyberKnife m6 counterparts, while simultaneously reducing treatment delivery times.
Keyword:
CyberKnife
noncoplanar
optimization
robotic radiotherapy
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Medical Physics 封面图
Medical Physics
IF:
3.2
论文数:
3.7W
被引数:
3.2W

机构

University of California System 封面图
University of California System
学者数:
37.7W
论文数: 33.8W
被引数: 6.6K
引用论文

引用论文

Determination of Total Protein Content of Bacterial Cells by SYPRO Staining and Flow Cytometry
err1999-07-01
err0
errOAAI
errMikhail V. Zubkov; Bernhard M. Fuchs; Heike Eilers; Peter H. Burkill; Rudolf Amann
err分享
err收藏
4π Non-Coplanar Liver SBRT: A Novel Delivery Technique
err2013-04-01
err158
PREAI
errDong, Peng; Lee, Percy; Ruan, Dan; Long, Troy; Romeijn, Edwin; Yang, Yingli; Low, Daniel; Kupelian, Patrick; Sheng, Ke
err分享
err收藏
Genetic algorithm for optimization of energy systems: Solution uniqueness, accuracy, Pareto convergence and dimension reduction
errENERGY
IF9.4
err2017-01-01
err37
PREAI
errGanjehkaviri, A.; Jaafar, M. N. Mohd; Hosseini, S. E.; Barzegaravval, H.
err分享
err收藏
err分享
err收藏
学者 查看更多内容