arrow
返回

A current sensorless MPPT control method for a stand-alone-type PV generation system

delete2006-08-17
delete5
PRE
AI
K
Kazutaka Itako *
T
Takeaki Mori
DOI:10.1002/eej.20424delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
In this paper, a current sensorless MPPT control method for a stand-alone-type PV generation system is proposed. This control method offers advantages of the simplified hardware configuration and low cost by using only one sensor to measure the PV Output voltage. When used as a stand-alone-type with a battery load, the experimental results show that the estimated values of PV output current are accurate, and the use of the proposed MPPT control increases the PV generated energy by 16.3% compared to the conventional system. Furthermore, the authors clarified that the proposed method has an extremely high UUF (useful utilization factor) of 98.7%. (c) 2006 Wiley Periodicals, Inc.
Keyword:
PV generation system
MPPT control
current sensorless
step-up DC-DC converter
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

E
Electrical Engineering in Japan
IF:
0.6
论文数:
158
被引数:
598

机构

暂无机构信息
引用论文

引用论文

Tissue response during monofocal and bifocal leg lengthening in patients
err2006-01-01
err0
errOAAI
errGudrun Trøite Aarnes; Harald Steen; Leif Pål Kristiansen; Per Ludvigsen; Olav Reikerås
err分享
err收藏