返回
A daylight-oriented multi-objective optimisation of complex fenestration systems
DOI:10.1016/j.buildenv.2021.107828.png)
摘要
En 中文
Complex fenestration systems (CFS) are effective daylighting strategies that improve daylight performance in indoor living spaces. Nevertheless, the design of CFS is complex as it requires specialised knowledge in optical physics and advanced building simulation. This paper presents an evaluation method (CFStrace) to optimise the CFS design in a multi-objective optimisation setting. The method takes into account both architectural and environmental conditions that maximise the effect of light redirection for complex fenestration systems to its full potential. The research aims to demonstrate a multi-objective and multi-scenario optimisation methodology for designing complex fenestration systems. The parameters of the optimisation problem can be easily changed due to the parametric nature of the modelling environment used. Thus, this gives designers the flexibility to adjust the CFS parameters and decrease their discretisation. To support the presented methodology, a case study is presented to demonstrate the design process and guide designers in selecting the best design option. The case study involves the design optimisation of a sinewave-shaped light redirecting panel by tweaking its geometrical parameters and comparing the optimised result with existing light redirecting panels. The case study results indicate that optimising a CFS according to the architectural design can improve daylight metrics (such as improving the useful daylight illuminance (UDI) by +10%). The case study reveals the importance of addressing architectural and environmental constraints when designing CFS as the optimised design can differ with changing parameters such as the room depth or panel height.
Keyword:
Multi-objective optimisation
Complex fenestration systems
CFStrace
Forward raytracing
Daylighting
Parametric design
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
IF:
7.6
论文数:
1.4W
被引数:
6.6W
机构
暂无机构信息
引用论文
State-of-the-art review of solar design tools and methods for assessing daylighting and solar potential for building-integrated photovoltaics太阳能设计工具和方法的最新审查,用于评估建筑集成光伏的采光和太阳能潜力
CFStrace: An evaluation method to include complex fenestration systems in the facade design process
SOLAR ENERGY
IF6.6
Useful daylight illuminances: A replacement for daylight factors有用的日光照明: 日光因子的替代
ENERGY AND BUILDINGS
IF7.1