arrow
返回

A deep convolutional neural network for diffuse correlation tomography

delete2025-02-26
delete0
delete
OA
AI
J
Jiaxin Liu
J
Jihui Wang
Y
Yu Shang *
DOI:10.1063/5.0255686delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Near-infrared diffuse correlation tomography (DCT) is an emerging technology for tomographic imaging of blood flow index (BFI) in biological tissues through quantifying the light electric field temporal autocorrelation function. With the conventional approaches, proper reconstruction of BFI images is a challenging task from the limited DCT signals due to the severe imbalance between the optical measurements and the voxels to be reconstructed. In this study, we proposed a complete deep learning solution for DCT, including a dataset containing massive prior information for network training, a long short-term memory neural network for DCT signal denoising, as well as a deep convolutional neural network for mapping the DCT signals into the tomographic BFI images. The proposed deep learning solution was comprehensively validated through both computer simulations and phantom experiments, demonstrating its strong superiority over the conventional approach for precise and robustness reconstructions of the target BFI anomalies, with much better performance in reducing errors (i.e., the mean absolute error was reduced by 26.1 times) and preserving fine structure (i.e., the structure similarity index measure was increased by 12.8 times). The proper establishment of a deep learning strategy enables future exploration of the microvasculature blood flow mechanism on pathological tissues even from the limited DCT signals.
Keyword:
BLOOD-FLOW

期刊

Applied Physics Letters 封面图
Applied Physics Letters
IF:
3.6
论文数:
10.4W
被引数:
17.8W

机构

D
Dongguan University of Technology
学者数:
5.2K
论文数: 4.5K
被引数: 7.8K
引用论文

引用论文

Impact of Reconstruction Algorithms on Diffuse Correlation Tomography Blood Flow Imaging
err2020-01-01
err5
errOAAI
errZuo, Jia; Zhang, Xiaojuan; Lu, Jianju; Gui, Zhiguo; Shang, Yu
err分享
err收藏
Electronic structure of MgB2
err2002-05-01
err0
PREAI
errP Modak; R S Rao; B K Godwal; S K Sikka
err分享
err收藏
The Use of Microwaves Ablation in the Treatment of Epiphyseal Osteoid Osteomas
err2013-08-30
err0
PREAI
errAntonio Basile; Giovanni Failla; Angelo Reforgiato; Giovanni Scavone; Elena Mundo; Martina Messina; Giuseppe Caltabiano; Francesco Arena; Viola Ricceri; Antonio Scavone; Salvatore Masala
err分享
err收藏
Three-dimensional flow contrast imaging of deep tissue using noncontact diffuse correlation tomography
err2014-03-24
err56
errOAAI
errLin, Yu; Huang, Chong; Irwin, Daniel; He, Lian; Shang, Yu; Yu, Guoqiang
err分享
err收藏
An objective analysis of sebum, pH and moisture levels of the external ear canal skin
err2015-05-01
err0
PREAI
errArzu Tuzuner; Seden Akdagli; Tangul Sen; Sule Demirci; Nilufer Tarimci; Refik Caylan
err分享
err收藏
Validation of diffuse correlation spectroscopy for muscle blood flow with concurrent arterial spin labeled perfusion MRI
err2007-01-01
err217
errOAAI
errYu, Guoqiang; Floyd, Thomas F.; Durduran, Turgut; Zhou, Chao; Wang, Jiongjiong; Detre, John A.; Yodh, Arjun G.
err分享
err收藏
Metal–Insulator Transition for V2O3Powder Observed Using a Soft X-ray Emission Spectrometer
err2010-05-15
err0
PREAI
errYoichi Ishiwata; Satoshi Suehiro; Yasuyuki Soi; Yasuhisa Tezuka; Osamu Morimoto; Xu-Guang Zheng
err分享
err收藏
学者 查看更多内容