arrow
返回

A Frequency-Selective pH-Responsive paraCEST Agent

delete2020-10-06
delete12
delete
OA
AI
S
S. James Ratnakar
S
Sara Chirayil
A
Alexander Funk
S
Shanrong Zhang
J
João Filipe Queiró
C
Carlos F. G. C. Geraldes
Z
Zoltán Kovács
A
A. Dean Sherry *
DOI:10.1002/anie.202008888delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Paramagnetic chemical exchange saturation transfer (paraCEST) agents are well-suited for imaging tissue pH because the basis of CEST, chemical exchange, is inherently sensitive to pH. Several previous pH-sensitive paraCEST agents were based on an exchanging Ln(3+)-bound water molecule as the CEST antenna but this design often added additional line-broadening to the bulk water signal due toT(2)exchange. We report herein a pH-sensitive paraCEST agent that lacks an inner-sphere water molecule but contains one Ln-bound -OH group for CEST activation. The Yb(3+)complex, Yb(1), displayed a single, highly shifted CEST peak originating from the exchangeable Yb-OH proton, the frequency of which changed over the biologically relevant pH range. CEST images of phantoms ranging in pH from 6 to 8 demonstrate the potential of this agent for imaging pH. Initial rodent imaging studies showed that Gd(1) remains in the vascular system much longer than anticipated but is cleared slowly via renal filtration.
Keyword:
contrast agents
imaging agents
lanthanide complexes
paraCEST
pH sensing
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Angewandte Chemie-International Edition 封面图
Angewandte Chemie-International Edition
IF:
16.9
论文数:
5.7W
被引数:
53.0W

机构

U
university of texas southwestern medical center dallas
学者数:
1.8W
论文数: 1.4W
被引数: 28
U
university of texas system
学者数:
18.5W
论文数: 15.6W
被引数: 210
U
universidade de coimbra
学者数:
1.9W
论文数: 1.6W
被引数: 16
学者 查看更多机构
引用论文

引用论文

A General MRI-CEST Ratiometric Approach for pH Imaging: Demonstration of in Vivo pH Mapping with lobitridol
err2014-10-02
err167
errOAAI
errLongo, Dario L.; Sun, Phillip Zhe; Consolino, Lorena; Michelotti, Filippo C.; Uggeri, Fulvio; Aime, Silvio
err分享
err收藏
pH Imaging of Mouse Kidneys In Vivo Using a Frequency-Dependent paraCEST Agent
err2015-07-14
err54
errOAAI
errWu, Yunkou; Zhang, Shanrong; Soesbe, Todd C.; Yu, Jing; Vinogradov, Elena; Lenkinski, Robert E.; Sherry, A. Dean
err分享
err收藏
Measuring in vivo tumor pHe with CEST-FISP MRI
err2011-10-25
err104
errOAAI
errSheth, Vipul R.; Li, Yuguo; Chen, Liu Qi; Howison, Christine M.; Flask, Chris A.; Pagel, Mark D.
err分享
err收藏
Maximizing T2-Exchange in Dy3+DOTA-(amide)X Chelates: Fine-Tuning the Water Molecule Exchange Rate for Enhanced T2 Contrast in MRI
err2014-01-03
err40
errOAAI
errSoesbe, Todd C.; Ratnakar, S. James; Milne, Mark; Zhang, Shanrong; Do, Quyen N.; Kovacs, Zoltan; Sherry, A. Dean
err分享
err收藏
err分享
err收藏
err分享
err收藏
Detección de proteasas extracelulares en especies de Mucor
err2005-06-01
err0
PREAI
errMaria Helena Alves; Galba M. de Campos-Takaki; Kaoru Okada; Inês Helena Ferreira Pessoa; Adauto Ivo Milanez
err分享
err收藏
学者 查看更多内容