返回
A fuzzy-split range control system applied to a fermentation process
DOI:10.1016/j.biortech.2013.05.083.png)
摘要
En 中文
In this study it was proposed the application of a fuzzy-PI controller in tandem with a split range control strategy to regulate the temperature inside a fermentation vat. Simulations were carried out using different configurations of fuzzy controllers and split range combinations for regulatory control. The performance of these control systems were compared using conventional integral of error criteria, the demand of utilities and the control effort. The proposed control system proved able to adequately regulate the temperature in all the tests. Besides, considering a similar ITAE index and using the energetically most efficient split range configuration, fuzzy-PI controller provided a reduction of approximately 84.5% in the control effort and of 6.75% in total demand of utilities by comparison to a conventional PI controller. (C) 2013 Elsevier Ltd. All rights reserved.
Keyword:
Fermentation
Fuzzy control
Split range control
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
IF:
9
论文数:
3.3W
被引数:
17.3W