arrow
返回

A general method for assessing brain-computer interface performance and its limitations

delete2014-03-24
delete17
delete
OA
AI
N
N. Jeremy Hill *
A
Ann-Katrin Häuser
G
Gerwin Schalk
DOI:10.1088/1741-2560/11/2/026018delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Objective. When researchers evaluate brain computer interface (BCI) systems, we want quantitative answers to questions such as: How good is the system's performance? How good does it need to be? and: Is it capable of reaching the desired level in future? In response to the current lack of objective, quantitative, study-independent approaches, we introduce methods that help to address such questions. We identified three challenges: (I) the need for efficient measurement techniques that adapt rapidly and reliably to capture a wide range of performance levels; (II) the need to express results in a way that allows comparison between similar but non-identical tasks; (III) the need to measure the extent to which certain components of a BCI system (e.g. the signal processing pipeline) not only support BCI performance, but also potentially restrict the maximum level it can reach. Approach. For challenge (I), we developed an automatic staircase method that adjusted task difficulty adaptively along a single abstract axis. For challenge (II), we used the rate of information gain between two Bernoulli distributions: one reflecting the observed success rate, the other reflecting chance performance estimated by a matched random-walk method. This measure includes Wolpaw's information transfer rate as a special case, but addresses the latter's limitations including its restriction to item-selection tasks. To validate our approach and address challenge (III), we compared four healthy subjects' performance using an EEG-based BCI, a 'Direct Controller' (a high-performance hardware input device), and a 'Pseudo-BCI Controller' (the same input device, but with control signals processed by the BCI signal processing pipeline). Main results. Our results confirm the repeatability and validity of our measures, and indicate that our BCI signal processing pipeline reduced attainable performance by about 33% (21 bits min(-1)). Significance. Our approach provides a flexible basis for evaluating BCI performance and its limitations, across a wide range of tasks and task difficulties.
Keyword:
brain-computer interface
neuroprosthetics
performance evaluation
information gain
information transfer rate

期刊

Journal of Neural Engineering 封面图
Journal of Neural Engineering
IF:
3.8
论文数:
4.0K
被引数:
1.4W

机构

S
state university of new york (suny) system
学者数:
6.5W
论文数: 5.8W
被引数: 65
引用论文

引用论文

err分享
err收藏
Interactions of Lemon, Sucrose and Citric Acid in Enhancing Citrus, Sweet and Sour Flavors
err2017-10-09
err0
errOAAI
errMaria G Veldhuizen; Ashik Siddique; Sage Rosenthal; Lawrence E Marks
err分享
err收藏
A brain-actuated wheelchair:: Asynchronous and non-invasive Brain-computer interfaces for continuous control of robots
err2008-09-01
err509
errOAAI
errGalan, F.; Nuttin, M.; Lew, E.; Ferrez, P. W.; Vanacker, G.; Philips, J.; Millan, J. del R.
err分享
err收藏
Registration of Arthur 71 and Abe Wheat1 (Reg. Nos. 560 and 562)
err1975-09-01
err0
PREAI
errF. L. Patterson; R. L. Gallun; J. J. Roberts; R. E. Finney; G. E. Shaner
err分享
err收藏
Transforming growth factor ?2, but not ?1 and ?3, is critical for early rat lung branching
err2000-04-01
err0
errOAAI
errJason Liu; Irene Tseu; Jinxia Wang; Keith Tanswell; Martin Post
err分享
err收藏
Polymer Light-Emitting Electrochemical Cells
err1995-08-25
err0
PREAI
errQibing Pei; Gang Yu; Chi Zhang; Yang Yang; Alan J. Heeger
err分享
err收藏
Preparation and characterization of ultra-small, monodisperse Co Fe3-O4 nanoparticles
err2023-02-01
err0
PREAI
errShoronia N. Cross; Majed Fataftah; Antranik Jonderian; Eric McCalla; Amy Szuchmacher Blum
err分享
err收藏
学者 查看更多内容