返回
A geometric-sensitivity-difference based algorithm improves object depth-localization for diffuse optical tomography in a circular-array outward-imaging geometry
DOI:10.1118/1.4771957.png)
摘要
En 中文
Purpose: To improve object depth-localization for diffuse optical tomography (DOT) in a circular-array outward-imaging geometry that is subjected to strong sensitivity variation with respect to imaging depth. Methods: The authors introduce an alternative DOT image reconstruction approach that optimizes the data-model fit based on the paired measurements corresponding to two pairs of source-detector that share either the source or the detector, in comparison to the conventional method that optimizes the data-model fit based on the unpaired measurements corresponding to individual pairs of source-detector. This alternative approach, namely, geometric-sensitivity-difference (GSD) method, effectively reduces the variation of the reconstruction sensitivity with respect to imaging depth. The DOT image reconstruction based on GSD-scheme applied to same-source source-detector pairs is demonstrated using simulated and experimental continuous-wave measurements in a circular-array outward-imaging geometry, of which the native sensitivity varies strongly with respect to the depth. The outcomes of GSD-based image reconstruction are compared to those of two other methods: one is the conventional baseline method that utilizes the native sensitivity but does not involve depth-compensating scheme; and the other is a reference-compensation approach that employs active and depth-adapted compensation scheme to counteract the dependence of the reconstruction sensitivity with respect to imaging depth. Results: The GSD method generally outperforms the other two methods in localizing the depth of single object, resolving two objects that are azimuthally separated, and estimating the optical property of single object or azimuthally separated dual objects. The GSD method, however, demands more computations due to an increase of the element size of the resulted sensitivity matrix and more matrix multiplications. Conclusions: The GSD method improves the depth localization in the circular-array outward-imaging geometry, by taking advantage of the paired measurements of two source-sharing source-detector-pairs to passively and effectively homogenize the sensitivity of the reconstruction with respect to imaging depth. c 2013 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4771957]
Keyword:
image reconstruction
diffuse optical tomography
sensitivity
photon migration in tissue
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
IF:
3.2
论文数:
3.7W
被引数:
3.2W
机构
引用论文
Improving depth resolution of diffuse optical tomography with a layer-based sigmoid adjustment method
OPTICS EXPRESS
IF3.3
Development of a compensation algorithm for accurate depth localization in diffuse optical tomography
OPTICS LETTERS
IF3.3
Trans-rectal ultrasound-coupled near-infrared optical tomography of the prostate Part I: Simulation
OPTICS EXPRESS
IF3.3

