arrow
返回

A High Precision Terahertz Wave Image Reconstruction Algorithm

delete2016-07-22
delete19
delete
OA
AI
Q
Qijia Guo
T
Tianying Chang *
G
Guoshuai Geng
C
Chengyan Jia
H
Hong‐Liang Cui
DOI:10.3390/s16071139delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
With the development of terahertz (THz) technology, the applications of this spectrum have become increasingly wide-ranging, in areas such as non-destructive testing, security applications and medical scanning, in which one of the most important methods is imaging. Unlike remote sensing applications, THz imaging features sources of array elements that are almost always supposed to be spherical wave radiators, including single antennae. As such, well-developed methodologies such as Range-Doppler Algorithm (RDA) are not directly applicable in such near-range situations. The Back Projection Algorithm (BPA) can provide products of high precision at the the cost of a high computational burden, while the Range Migration Algorithm (RMA) sacrifices the quality of images for efficiency. The Phase-shift Migration Algorithm (PMA) is a good alternative, the features of which combine both of the classical algorithms mentioned above. In this research, it is used for mechanical scanning, and is extended to array imaging for the first time. In addition, the performances of PMA are studied in detail in contrast to BPA and RMA. It is demonstrated in our simulations and experiments described herein that the algorithm can reconstruct images with high precision.
Keyword:
Phase-shift Migration Algorithm
terahertz wave image
high precision image reconstruction
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Sensors 封面图
Sensors
IF:
3.5
论文数:
7.2W
被引数:
20.9W

机构

J
Jilin University
学者数:
8.7W
论文数: 5.6W
被引数: 8.9K
引用论文

引用论文

Role of Brush Biopsy and DNA Cytometry for Prevention, Diagnosis, Therapy, and Followup Care of Oral Cancer
err2011-01-01
err0
errOAAI
errAlfred Böcking; Christoph Sproll; Nikolas Stöcklein; Christian Naujoks; Rita Depprich; Norbert R. Kübler; Jörg Handschel
err分享
err收藏
Dust Levitation on Asteroids
err1996-11-01
err0
errOAAI
errPascal Lee
err分享
err收藏
A new model mouse for Duchenne muscular dystrophy produced by 2.4 Mb deletion of dystrophin gene using Cre-loxP recombination system
err2005-03-01
err0
PREAI
errHiroe Kudoh; Haruko Ikeda; Makoto Kakitani; Akiko Ueda; Michiko Hayasaka; Kazuma Tomizuka; Kazunori Hanaoka
err分享
err收藏
err分享
err收藏
Fourier-Sparsity Integrated Method for Complex Target ISAR Imagery
errSENSORS
IF3.5
err2015-01-26
err18
errOAAI
errGao, Xunzhang; Liu, Zhen; Chen, Haowen; Li, Xiang
err分享
err收藏
err分享
err收藏
学者 查看更多内容