arrow
返回

A microfluidic SELEX prototype

delete2005-11-29
delete137
PRE
AI
G
Glen Hybarger
J
Joseph Bynum
R
Robert F. Williams
J
James J. Valdés
J
James P. Chambers
DOI:10.1007/s00216-005-0089-3delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Aptamers are nucleic acid binding species capable of recognizing a wide variety of targets ranging from small organic molecules to supramolecular structures, including organisms. They are isolated from combinatorial libraries of synthetic nucleic acid by an iterative process referred to as SELEX (Systematic Evolution of Ligands by Exponential Enrichment). Here we describe an automated microfluidic, microline-based assembly that uses LabView-controlled actuatable valves and a PCR machine, and which is capable of the selection and synthesis of an anti-lysozyme aptamer as verified by sequence analysis. The microfluidic prototype described is 1) a simple apparatus that is relatively inexpensive to assemble, making automated aptamer selection accessible to many investigators, and 2) useful for the continued morphing of macro -> meso -> microfabricated structures until a convergence to a few functional systems evolves and emerges, partly or completely achieving simpler, smaller and more rapid SELEX applications.
Keyword:
SELEX
microfluidic
miniaturized
aptamer
prototype

期刊

Analytical and Bioanalytical Chemistry 封面图
Analytical and Bioanalytical Chemistry
IF:
3.8
论文数:
1.8W
被引数:
3.5W

机构

暂无机构信息
引用论文

引用论文

Electrochemical enzyme immunoassays on microchip platforms
err2001-10-02
err187
PREAI
errWang, J; Ibáñez, A; Chatrathi, MP; Escarpa, A
err分享
err收藏
Microchip device for performing enzyme assays
err1997-09-01
err459
PREAI
errHadd, AG; Raymond, DE; Halliwell, JW; Jacobson, SC; Ramsey, JM
err分享
err收藏
Temporal lobe epilepsy caused by domoic acid intoxication: Evidence for glutamate receptor–mediated excitotoxicity in humans
err2004-10-08
err0
PREAI
errFernando Cendes; Frederick Andermann; Stirling Carpenter; Robert J. Zatorre; Neil R. Cashman
err分享
err收藏
Liquid chromatography on-chip:: progression towards a μ-total analysis system
errANALYST
IF3.3
err2000-01-01
err49
PREAI
errMcEnery, M; Tan, AM; Alderman, J; Patterson, J; O'Mathuna, SC; Glennon, JD
err分享
err收藏
Development of multichannel devices with an array of electrospray tips far high-throughput mass spectrometry
err2000-05-31
err142
PREAI
errLiu, HH; Felten, C; Xue, QF; Zhang, BL; Jedrzejewski, P; Karger, BL; Foret, F
err分享
err收藏
err分享
err收藏
New insights into the CO2-steady and pH-steady cultivations of two microalgae based on continuous online parameter monitoring
err2019-03-01
err0
PREAI
errXupeng Cao; Yimei Xi; Jiao Liu; Yadong Chu; Peichun Wu; Miao Yang; Zhanyou Chi; Song Xue
err分享
err收藏
A miniature integrated device for automated multistep genetic assays
err2000-06-15
err222
errOAAI
errAnderson, Rolfe C.; Su, Xing; Bogdan, Gregory J.; Fenton, Jeffery
err分享
err收藏
学者 查看更多内容