摘要

En 中文
To address the demands in healthcare and industrial settings for spatially resolved magnetic imaging, we present a modular optically pumped magnetometer (OPM) system comprising a multi-sensor array of highly sensitive quantum magnetometers. This system is designed and built to facilitate fast prototyping and testing of new measurement schemes by enabling quick reconfiguration of the self-contained laser and sensor modules as well as allowing for the construction of various array layouts with a shared light source. The modularity of this system facilitates the development of methods for managing high-density arrays for magnetic imaging. The magnetometer sensitivity and bandwidth are first characterised in both individual channel and differential gradiometer configurations before testing in a real-world magnetoencephalography environment by measuring alpha rhythms from the brain of a human participant. We demonstrate the OPM system in a first-order axial gradiometer configuration with a magnetic field gradient sensitivity of 10 fT / cm / Hz at a baseline of 4.5 cm. Single-channel operation achieved a sensitivity of 65 fT / Hz . Bandwidths exceeding 200 Hz were achieved for two independent modules. The system's increased temporal resolution allows for the measurement of spinal cord signals, which we demonstrate by using phantom signal trials and comparing with an existing commercial sensor.
Keyword:
modular
optically
pumped
magnetometer
array
OPM
MEG

期刊

Quantum Science and Technology 封面图
Quantum Science and Technology
IF:
5
论文数:
1.4K
被引数:
5.1K

机构

U
University of Sussex
学者数:
9.2K
论文数: 9.3K
被引数: 27
P
physikalisch-technische bundesanstalt (ptb)
学者数:
2.1K
论文数: 1.6K
被引数: 0
引用论文

引用论文

Proteomic analysis of heparin-binding proteins from human seminal plasma: a step towards identification of molecular markers of male fertility
err2009-11-27
err0
PREAI
errVijay Kumar; Md Imtaiyaz Hassan; Anil Kumar Tomar; Tara Kashav; Jaya Nautiyal; Sarman Singh; Tej P. Singh; Savita Yadav
err分享
err收藏
Subpicotesla atomic magnetometry with a microfabricated vapour cell
err2007-11-01
err368
PREAI
errShah, Vishal; Knappe, Svenja; Schwindt, Peter D. D.; Kitching, John
err分享
err收藏
Sperm DNA Damage Evaluation Techniques
err2013-01-02
err0
errOAAI
errMohannad Dugum; Jay I. Sandlow; Robert E. Brannigan
err分享
err收藏
Evaluation of aneuploidy and DNA damage in human spermatozoa: applications in field studies
err2000-09-01
err0
errOAAI
errS. D. Perreault; J. Rubes; W. A. Robbins; D. P. Evenson; S. G. Selevan
err分享
err收藏
Sperm chromatin damage impairs human fertility
err2000-01-01
err0
errOAAI
errMarcello Spanò; Jens P Bonde; Henrik I Hjøllund; Henrik A Kolstad; Eugenia Cordelli; Giorgio Leter
err分享
err收藏
Four-channel optically pumped atomic magnetometer for magnetoencephalography
err2016-06-29
err153
errOAAI
errColombo, Anthony P.; Carter, Tony R.; Borna, Amir; Jau, Yuan-Yu; Johnson, Cort N.; Dagel, Amber L.; Schwindt, Peter D. D.
err分享
err收藏
Recent advancements in the SQUID magnetospinogram system
err2017-05-03
err20
PREAI
errAdachi, Yoshiaki; Kawai, Jun; Haruta, Yasuhiro; Miyamoto, Masakazu; Kawabata, Shigenori; Sekihara, Kensuke; Uehara, Gen
err分享
err收藏
学者 查看更多内容