Electrical impedance tomography (EIT) is a non-ionizing real-time imaging tool for bedside pulmonary imaging. Dynamic cross-sectional images of ventilation and perfusion can be produced in real time with fast algorithms from measured voltage data arising from current applied on electrodes placed around the circumference of the patient's chest. The D-bar method is a direct (non-iterative) reconstruction algorithm for EIT that uses equations of inverse scattering to independently reconstruct the conductivity at each point in the region of interest. However, this nonlinear reconstruction method has a computational complexity that makes real-time imaging a challenge. At the same time, it has the attributes that it does not require successive solutions of the forward problem, as is the case with iterative methods, and it is trivially parallelizable in the spatial variable. Here, we present a novel multithreaded implementation of the D-bar method with a front-end MATLAB/Octave program interfaced with C code that uses the pthreads library. The implementation is analyzed on several different platforms with concurrent threads ranging from 2 to 32 for spatial grids of several sizes. We demonstrate that on a CPU with many cores, very high frame rates (50 frames/s) with high resolution (6000 grid points) are achievable, and on a single AMD CPU real-time reconstructions (faster than 30 frames/s) are achieved with this implementation using 10 or more threads on a grid of 1969 points.
Keyword:
Electrical impedance tomography
Multithreading
D-bar algorithm
Real-time imaging
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Nature Computational Science 封面图
Nature Computational Science
IF:
18.3
论文数:
3.1K
被引数:
4.0K

机构

G
Gonzaga University
学者数:
344
论文数: 286
被引数: 357
C
Colorado State University System
学者数:
1.3W
论文数: 1.0W
被引数: 3
C
colorado state university fort collins
学者数:
8.1K
论文数: 6.1K
被引数: 2
学者 查看更多机构
引用论文

引用论文

err
IF0
err2024-07-29
err0
PREAI
err
err分享
err收藏
err
IF0
err
err0
PREAI
err
err分享
err收藏
Regional Lung Perfusion Analysis in Experimental ARDS by Electrical Impedance and Computed Tomography通过电阻抗和计算机断层扫描对实验性ARDS的局部肺灌注分析
err2021-01-01
err40
PREAI
errKircher, Michael; Elke, Gunnar; Stender, Birgit; Hernandez Mesa, Maria; Schuderer, Felix; Doessel, Olaf; Fuld, Matthew K.; Halaweish, Ahmed F.; Hoffman, Eric A.; Weiler, Norbert; Frerichs, Inez
err分享
err收藏
Development of a Portable Electrical Impedance Tomography Device for Online Thrombus Detection in Extracorporeal-Circulation Equipment
err2021-02-01
err19
PREAI
errChen, Huaijin; Yao, Jiafeng; Yang, Lu; Liu, Kai; Chen, Bai; Li, Jianping; Takei, Masahiro
err分享
err收藏
学者 查看更多内容