arrow
返回

A new column-generation-based algorithm for VMAT treatment plan optimization

delete2012-06-22
delete53
delete
OA
AI
F
Fei Peng *
X
Xun Jia
X
Xuejun Gu
M
Marina A. Epelman
H
H. Edwin Romeijn
S
Steve Jiang
DOI:10.1088/0031-9155/57/14/4569delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
We study the treatment plan optimization problem for volumetric modulated arc therapy (VMAT). We propose a new column-generation-based algorithm that takes into account bounds on the gantry speed and dose rate, as well as an upper bound on the rate of change of the gantry speed, in addition to MLC constraints. The algorithm iteratively adds one aperture at each control point along the treatment arc. In each iteration, a restricted problem optimizing intensities at previously selected apertures is solved, and its solution is used to formulate a pricing problem, which selects an aperture at another control point that is compatible with previously selected apertures and leads to the largest rate of improvement in the objective function value of the restricted problem. Once a complete set of apertures is obtained, their intensities are optimized and the gantry speeds and dose rates are adjusted to minimize treatment time while satisfying all machine restrictions. Comparisons of treatment plans obtained by our algorithm to idealized IMRT plans of 177 beams on five clinical prostate cancer cases demonstrate high quality with respect to clinical dose-volume criteria. For all cases, our algorithm yields treatment plans that can be delivered in around 2 min. Implementation on a graphic processing unit enables us to finish the optimization of a VMAT plan in 25-55 s.
Keyword:
MODULATED ARC THERAPY
DIRECT APERTURE OPTIMIZATION
RADIATION-THERAPY
IMRT

期刊

Physics in Medicine and Biology 封面图
Physics in Medicine and Biology
IF:
3.4
论文数:
1.4W
被引数:
3.1W

机构

U
University of Michigan
学者数:
6.4W
论文数: 5.3W
被引数: 124
U
university of michigan system
学者数:
9.1W
论文数: 8.6W
被引数: 133
引用论文

引用论文

Direct aperture optimization: A turnkey solution for step-and-shoot IMRT
err2002-05-13
err345
PREAI
errShepard, DM; Earl, MA; Li, XA; Naqvi, S; Yu, C
err分享
err收藏
err分享
err收藏
Multicriteria VMAT optimization
err2012-01-12
err109
errOAAI
errCraft, David; McQuaid, Dualta; Wala, Jeremiah; Chen, Wei; Salari, Ehsan; Bortfeld, Thomas
err分享
err收藏
Single-Arc IMRT?
err2008-12-10
err171
PREAI
errBortfeld, Thomas; Webb, Steve
err分享
err收藏
GPU-based ultra-fast dose calculation using a finite size pencil beam model
err2009-10-01
err96
errOAAI
errGu, Xuejun; Choi, Dongju; Men, Chunhua; Pan, Hubert; Majumdar, Amitava; Jiang, Steve B.
err分享
err收藏
VOLUMETRIC INTENSITY-MODULATED ARC THERAPY VS. CONVENTIONAL IMRT IN HEAD-AND-NECK CANCER: A COMPARATIVE PLANNING AND DOSIMETRIC STUDY
err2009-05-01
err414
PREAI
errVerbakel, Wilko F. A. R.; Cuijpers, Johan P.; Hoffmans, Daan; Bieker, Michael; Slotman, Ben J.; Senan, Suresh
err分享
err收藏
学者 查看更多内容