arrow
返回

A new CSTR method for scale inhibitor evaluation

delete2022-06-01
delete5
PRE
AI
Z
Zhaoyi Dai *
S
Samridhdi Paudyal
C
Chong Dai
S
Saebom Ko
Y
Yue Zhao
王欣 封面图
王欣 (Xin Wang)
W
Wei Li
Y
Yi-Tsung Lu
A
Amy T. Kan
M
Mason B. Tomson
DOI:10.1016/j.cej.2022.135351delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
In various industries, the mineral scale control is critical to ensure productivity, facility integrity, and health and safety. Among different scaling control methods, the scale inhibitor is one of the most commonly used and economic methods. To optimize scale inhibitor applications, it is required to accurately and efficiently evaluate scale inhibitor performances, and determine the required minimum inhibitor concentration (MIC). However, the traditional NACE static bottle tests, dynamic scale loop (DSL) tests, and the batch laser test are limited by their testing conditions, consumable costs, or testing efficiency, especially when minimal inhibitor information is available. This study developed a new brine chemistry inhibitor (BCIn) CSTR (continuous stirring tank reactor) evaluation method to overcome these limitations. In the BCIn CSTR testing, the supersaturated solution with the same SI is pumped into the reactor without the continuous supply of scale inhibitors. As a result, the scale inhibitor concentration is diluted exponentially, which significantly accelerates the crystallization process and generates much sharper and more reproducible end point. More importantly, this study also developed a mechanistic model that correlates the crystallization processes of the BCIn CSTR and batch laser testing. This correlation model makes the BCIn CSTR method and the batch laser testing method equivalent in terms of scale inhibitor performance evaluation. Using this method, the inhibitor performance screening can usually be finished within 20 min with better accuracy and reproducibility (less than6.6% error). Furthermore, the MIC can be accurately determined by as few as one BCIn CSTR test using the correlation model, instead of via multiple lengthy batch laser tests. We believe this BCIn CSTR method can significantly improve the evaluation of scale inhibitor performance and MIC determination.
Keyword:
Mineral Scale
Turbidity
MIC
Anti-scalant
CSTR

期刊

Chemical Engineering Journal 封面图
Chemical Engineering Journal
IF:
13.2
论文数:
7.4W
被引数:
48.5W

机构

R
Rice University
学者数:
1.4W
论文数: 1.2W
被引数: 2.6W
C
China University of Geosciences
学者数:
3.7W
论文数: 2.8W
被引数: 4.3W
引用论文

引用论文

The six-flow reactor technology -: A review on fast catalyst screening and kinetic studies
err2000-07-10
err211
PREAI
errPérez-Ramírez, J; Berger, RJ; Mul, G; Kapteijn, F; Moulijn, JA
err分享
err收藏
Mathematical inhibitor model for barium sulfate scale control
err1996-04-03
err70
PREAI
errHe, SL; Kan, AT; Tomson, MB
err分享
err收藏
err
IF0
err
err0
PREAI
err
err分享
err收藏
VDJ gene usage among B-cell receptors in ABO-incompatible kidney transplantation determined by RNA-seq Transcriptomic analysis
err2017-11-28
err0
errOAAI
errHee Jung Jeon; Kwangsoo Kim; Jae-Ghi Lee; Joon Young Jang; Seongmin Choi; Taishi Fang; Ji-Jing Yan; Miyeun Han; Jong Cheol Jeong; Kyoung-Bun Lee; Tae Jin Kim; Curie Ahn; Jaeseok Yang
err分享
err收藏
err
IF0
err
err0
PREAI
err
err分享
err收藏
Development and Application of a New Theoretical Model for Additive Impacts on Mineral Crystallization
err2017-06-12
err33
PREAI
errDai, Zhaoyi; Zhang, Fangfu; Bhandari, Narayan; Deng, Guannan; Kan, Amy T.; Yan, Fei; Ruan, Gedeng; Zhang, Zhang; Liu, Ya; Lu, Alex Yi-Tsung; Tomson, Mason
err分享
err收藏
err分享
err收藏
Reduced professional efficacy is associated with a blunted salivary alpha-amylase awakening response
err2019-02-01
err0
PREAI
errKathleen Landolt; Paul Maruff; Ben Horan; Michael Kingsley; Glynda Kinsella; Paul D. O'Halloran; Matthew W. Hale; Bradley J. Wright
err分享
err收藏
学者 查看更多内容