arrow
返回

A new static visual field test algorithm: the Ambient Interactive ZEST (AIZE)

delete2023-09-11
delete4
delete
OA
AI
H
Hiroki Nomoto *
C
Chota Matsumoto
S
Sachiko Okuyama
S
Shinji Kimura
S
Satoshi Inoue
K
Kenzo Yamanaka
S
Shunji Kusaka
DOI:10.1038/s41598-023-42266-zdelete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Visual field (VF) test is one of the most vital tests in the diagnosis of glaucoma and to monitor the disease worsening. In the past couple of decades, the standard automated perimetry (SAP) test takes a major role in VF test for glaucoma patients. The SAP has been demanded to finish a test in short time without sacrificing accuracy. In this study, we developed and evaluated the performance of a new perimetric algorithm (ambient interactive zippy estimation by sequential testing (ZEST): AIZE) by computer simulation. AIZE is a modification of the ZEST procedure that utilizes the spatial information (weighted likelihood: WL) of neighboring test locations, which varies from the distance to the tested location, to estimate a visual threshold. Ten glaucomatous and 10 normal empirical visual field (VF) test results were simulated with five error conditions [(3% false positives (FP), 3% false negatives (FN)), (9% FP, 9% FN), (15% FP, 15% FN), (3% FP, 15% FN), (15% FP, 3% FN)]. The total number of test presentations and the root mean square error (RMSE) of the estimated visual sensitivities were compared among AIZE, the non-weighted test (WL=0) and the fixed-weighted test (WL=0.33). In both glaucomatous (G) and normal (N) VFs, the fixed-weighted test had the lowest number of test presentations (median G 256, N 139), followed by the AIZE (G 285, N 174) and the non-weighted test (G 303, N 195). The RMSE of the fixed-weighted test was lower (median 1.7 dB) than that of the AIZE (1.9 dB) and the non-weighted test (1.9 dB) for normal VFs, whereas the AIZE had a lower RMSE (3.2 dB) than the fixed-weighted test (4.5 dB) and the non-weighted test (4.0 dB) for glaucomatous VFs. Simulation results showed that AIZE had fewer test presentations than the non-weighted test strategy without affecting the accuracy for glaucomatous VFs. The AIZE is a useful time saving test algorithm in clinical settings.
Keyword:
THRESHOLD
GLAUCOMA
PERIMETER
VARIABILITY
RELIABILITY
STRATEGY
SITA
HEAD
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Scientific Reports 封面图
Scientific Reports
IF:
3.9
论文数:
28.0W
被引数:
83.5W

机构

暂无机构信息
引用论文

引用论文

Evidence-based Criteria for Assessment of Visual Field Reliability视野可靠性评估的循证标准
err2017-11-01
err125
errOAAI
errYohannan, Jithin; Wang, Jiangxia; Brown, Jamie; Chauhan, Balwantray C.; Boland, Michael V.; Friedman, David S.; Ramulu, Pradeep Y.
err分享
err收藏
Diagnostic Value of Subjective Memory Complaints Assessed with a Single Item in Dominantly Inherited Alzheimer’s Disease: Results of the DIAN Study
err2015-01-01
err0
errOAAI
errChristoph Laske; Hamid R. Sohrabi; Mateusz S. Jasielec; Stephan Müller; Niklas K. Koehler; Susanne Gräber; Stefan Förster; Alexander Drzezga; Felix Mueller-Sarnowski; Adrian Danek; Mathias Jucker; Randall J. Bateman; Virginia Buckles; Andrew J. Saykin; Ralph N. Martins; John C. Morris; Dominantly Inherited Alzheimer Network (DIAN)
err分享
err收藏
Mitigating transverse mode instability in a single-end pumped all-fiber laser oscillator with a scaling power of up to 2 kW
err2016-09-20
err0
PREAI
errBaolai Yang; Hanwei Zhang; Xiaolin Wang; Rongtao Su; Rumao Tao; Pu Zhou; Xiaojun Xu; Qisheng Lu
err分享
err收藏
The Influence of Intersubject Variability in Ocular Anatomical Variables on the Mapping of Retinal Locations to the Retinal Nerve Fiber Layer and Optic Nerve Head
err2013-09-09
err71
PREAI
errLamparter, Julia; Russell, Richard A.; Zhu, Haogang; Asaoka, Ryo; Yamashita, Takehiro; Ho, Tuan; Garway-Heath, David F.
err分享
err收藏
学者 查看更多内容