arrow
返回

A Review on PPG Compression Techniques and Implementations

delete2021-03-01
delete3
PRE
AI
S
Seeba Sulekha Abdulkader *
U
Uvais Qidwai
DOI:10.1109/IECBES48179.2021.9398812delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Photoplethysmography is a simple, widely used low cost technique to acquire important diagnostic information for assessing significant physiological parameters of the human body based on the amount of light reflected from or absorbed by the body. Photoplethysmogram (PPG) signal is recognized as one of the most powerful signals in the diagnosis of variations in heart rate and pulse rate, changes in blood oxygenation levels etc. With the great advancements in communication, information technology and Internet of Things (IoT), wearable health devices have been extensively used to measure PPG signals in telemedicine, remote health monitoring, ambulatory systems and in several mobile health systems. As these small wearable medical devices are battery operated and resource-constrained, dedicated and efficient compression techniques are required to optimally manage energy and memory requirements, without jeopardizing the relevant clinical morphologies. The paper focuses on the review of the existing PPG compression techniques, type of the compression used, the basic implementation and a comparative analysis of these techniques, which could help choose a suitable technique for specific applications.
Keyword:
Photoplethysmography
compression ratio
percentage root-mean-square difference
quantization
cross correlation
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

I
IEEE-EMBS Conference on Biomedical Engineering and Sciences: Leading Modern Healthcare Technology Enhancing Wellness
IF:
0
论文数:
2
被引数:
0

机构

Q
Qatar University
学者数:
8.9K
论文数: 9.0K
被引数: 16
引用论文

引用论文

Presence of Pili on the Surface of Francisella tularensis
err2004-05-01
err0
errOAAI
errHoracio Gil; Jorge L. Benach; David G. Thanassi
err分享
err收藏
Boosting the Battery Life of Wearables for Health Monitoring Through the Compression of Biosignals
err2017-10-01
err61
PREAI
errHooshmand, Mohsen; Zordan, Davide; Del Testa, Davide; Grisan, Enrico; Rossi, Michele
err分享
err收藏
Adaptive Band Limit Estimation based PPG data compression for portable home monitors
err2019-02-01
err12
PREAI
errSadhukhan, Deboleena; Pal, Saurabh; Mitra, Madhuchhanda
err分享
err收藏
err分享
err收藏
Rapid generation of specific protective immunity to Francisella tularensis
err1992-11-01
err0
errOAAI
errK L Elkins; D A Leiby; R K Winegar; C A Nacy; A H Fortier
err分享
err收藏
The use of photoplethysmography for assessing hypertension使用光电容积描记术评估高血压
err2019-06-26
err350
errOAAI
errElgendi, Mohamed; Fletcher, Richard; Liang, Yongbo; Howard, Newton; Lovell, Nigel H.; Abbott, Derek; Lim, Kenneth; Ward, Rabab
err分享
err收藏
学者 查看更多内容