arrow
返回

A standardized boundary element method volume conductor model

delete2002-05-01
delete839
delete
OA
AI
M
M. Fuchs *
J
Jörn Kastner
M
Michael Wagner
S
Susan M. Hawes
J
John S. Ebersole
DOI:10.1016/S1388-2457(02)00030-5delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Objectives: We used a 3-compartment boundary element method (BEM) model from an averaged magnetic resonance image (MRI) data set (Montreal Neurological Institute) in order to provide simple access to realistically shaped volume conductor models for source reconstruction, as compared to individually derived models. The electrode positions were transformed into the model's coordinate system, and the best fit dipole results were transformed back to the original coordinate system. The localization accuracy of the new approach was tested in a comparison with simulated data and with individual BEM models of epileptic spike data front several patients. Methods: The standard BEM model consisted of a total of 4770 nodes, which describe the smoothed cortical envelope, the outside of the skull, and the outside of the skin. The electrode positions were transformed to the model coordinate system by using 3-5 fiducials (nasion. left and right preauricular points, vertex, and inion). The transformation consisted of an averaged scaling factor and a rigid transformation (translation and rotation). The potential values at the transformed electrode positions were calculated by linear interpolation from the stored transfer matrix of the outer BEM compartment triangle net. After source reconstruction the best fit dipole results were transformed back into the original coordinate system by applying the inverse of the first transformation matrix. Results: Test-dipoles at random locations and with random orientations inside of a highly refined reference BEM model were used to simulate noise-free data. Source reconstruction results using a spherical and the standardized BEM volume conductor model were compared to the known dipole positions. Spherical head models resulted in mislocation errors at the base of the brain. The standardized BEM model was applied to averaged and unaveraged epileptic spike data from 7 patients. Source reconstruction results were compared to those achieved by 3 spherical shell models and individual BEM models derived front the individual MRI data sets. Similar errors to that evident with simulations were noted with spherical head models. Standardized and individualized BEM models were comparable. Conclusions: This new approach to head modeling performed significantly better than a simple spherical shell approximation. especially in basal brain areas, including the temporal lobe. By using a standardized head for the BEM setup, it offered an easier and faster access to realistically shaped volume conductor models as compared to deriving specific models from individual 3-dimensional MRI data. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.
Keyword:
boundary element method
EEG
triangle refinement
source reconstruction
localization accuracy
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Clinical Neurophysiology 封面图
Clinical Neurophysiology
IF:
3.6
论文数:
9.3K
被引数:
2.1W

机构

暂无机构信息
引用论文

引用论文

Applying Human-in-the-Loop to construct a dataset for determining content reliability to combat fake news
err2023-11-01
err0
errOAAI
errAlba Bonet-Jover; Robiert Sepúlveda-Torres; Estela Saquete; Patricio Martínez-Barco; Alejandro Piad-Morffis; Suilan Estevez-Velarde
err分享
err收藏
Automated Measurement of Net Water Uptake From Baseline and Follow-Up CTs in Patients With Large Vessel Occlusion Stroke
err2022-06-27
err0
errOAAI
errAtul Kumar; Yasheng Chen; Aaron Corbin; Ali Hamzehloo; Amin Abedini; Zeynep Vardar; Grace Carey; Kunal Bhatia; Laura Heitsch; Jamal J. Derakhshan; Jin-Moo Lee; Rajat Dhar
err分享
err收藏
A Case of Leptospirosis Diagnosed Early by flaB-PCR
err2003-01-01
err0
errOAAI
errNobuo KOIZUMI; Haruo WATANABE; Kazuo UMEZAWA; Tomoaki IIDUKA; Sadaki INOKUCHI
err分享
err收藏
Fatores associados à recorrência de quedas em uma coorte de idosos
err2016-11-01
err0
errOAAI
errDébora Regina de Oliveira Moura Abreu; Rosemeiry Capriata de Souza Azevedo; Ageo Mario Candido da Silva; Annelita Almeida Oliveira Reiners; Hellen Cristina Almeida Abreu
err分享
err收藏
学者 查看更多内容