arrow
返回

A tilted interference filter in a converging beam

delete2011-08-30
delete17
delete
OA
AI
M
M. G. Löfdahl *
V
V. M. J. Henriques
D
D. Kiselman
DOI:10.1051/0004-6361/201117305delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Context. Narrow-band interference filters can be tuned toward shorter wavelengths by tilting them from the perpendicular to the optical axis. This can be used as a cheap alternative to real tunable filters, such as Fabry-Perot interferometers and Lyot filters. At the Swedish 1-meter Solar Telescope, such a setup is used to scan through the blue wing of the Ca II H line. Because the filter is mounted in a converging beam, the incident angle varies over the pupil, which causes a variation of the transmission over the pupil, different for each wavelength within the passband. This causes broadening of the filter transmission profile and degradation of the image quality. Aims. We want to characterize the properties of our filter, at normal incidence as well as at different tilt angles. Knowing the broadened profile is important for the interpretation of the solar images. Compensating the images for the degrading effects will improve the resolution and remove one source of image contrast degradation. In particular, we need to solve the latter problem for images that are also compensated for blurring caused by atmospheric turbulence. Methods. We simulate the process of image formation through a tilted interference filter in order to understand the effects. We test the hypothesis that they are separable from the effects of wavefront aberrations for the purpose of image deconvolution. We measure the filter transmission profile and the degrading PSF from calibration data. Results. We find that the filter transmission profile differs significantly from the specifications. We demonstrate how to compensate for the image-degrading effects. Because the filter tilt effects indeed appear to be separable from wavefront aberrations in a useful way, this can be done in a final deconvolution, after standard image restoration with Multi-Frame Blind Deconvolution/Phase Diversity based methods. We illustrate the technique with real data.
Keyword:
instrumentation: interferometers
methods: observational
techniques: image processing
techniques: imaging spectroscopy
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Astronomy and Astrophysics 封面图
Astronomy and Astrophysics
IF:
5.8
论文数:
5.0W
被引数:
18.3W

机构

R
Royal Swedish Academy of Sciences
学者数:
386
论文数: 415
被引数: 1.5K
引用论文

引用论文

High-order aberration compensation with multi-frame blind deconvolution and phase diversity image restoration techniques
err2010-10-21
err32
errOAAI
errScharmer, G. B.; Lofdahl, M. G.; van Werkhoven, T. I. M.; Rodriguez, J. de la Cruz
err分享
err收藏
err分享
err收藏
Plasmacytoma of the Skull Base: A Meta-Analysis
err2015-08-20
err0
errOAAI
errShorook Na'ara; Moran Amit; Salem Billan; Ziv Gil
err分享
err收藏
err分享
err收藏
Interspecialty referral of oesophagogastric and pharyngolaryngeal cancers delays diagnosis and reduces patient survival: A matched case‐control study
err2020-02-20
err0
PREAI
errJon H. Bird; Elizabeth J. Williams; Kate J. Heathcote; Lachlan Ayres; Nilantha De Zoysa; Emma V. King; Sally D. Parry; S. A. Reza Nouraei
err分享
err收藏
没有更多内容