arrow
返回

Accelerated Quantitative 3D UTE-Cones Imaging Using Compressed Sensing

delete2022-10-01
delete15
delete
OA
AI
J
Jiyo Athertya
Y
Yajun Ma
A
Amir Masoud Afsahi
A
Alecio F. Lombardi
D
Dina Moazamian
S
Saeed Jerban
S
Sam Sedaghat
H
Hyungseok Jang *
DOI:10.3390/s22197459delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
In this study, the feasibility of accelerated quantitative Ultrashort Echo Time Cones (qUTE-Cones) imaging with compressed sensing (CS) reconstruction is investigated. qUTE-Cones sequences for variable flip angle-based UTE T-1 mapping, UTE adiabatic T-1 rho mapping, and UTE quantitative magnetization transfer modeling of macromolecular fraction (MMF) were implemented on a clinical 3T MR system. Twenty healthy volunteers were recruited and underwent whole-knee MRI using qUTE-Cones sequences. The k-space data were retrospectively undersampled with different undersampling rates. The undersampled qUTE-Cones data were reconstructed using both zero-filling and CS reconstruction. Using CS-reconstructed UTE images, various parameters were estimated in 10 different regions of interests (ROIs) in tendons, ligaments, menisci, and cartilage. Structural similarity, percentage error, and Pearson's correlation were calculated to assess the performance. Dramatically reduced streaking artifacts and improved SSIM were observed in UTE images from CS reconstruction. A mean SSIM of similar to 0.90 was achieved for all CS-reconstructed images. Percentage errors between fully sampled and undersampled CS-reconstructed images were below 5% for up to 50% undersampling (i.e., 2 x acceleration). High linear correlation was observed (>0.95) for all qUTE parameters estimated in all subjects. CS-based reconstruction combined with efficient Cones trajectory is expected to achieve a clinically feasible scan time for qUTE imaging.
Keyword:
compressed sensing
UTE
quantitative MRI
image reconstruction
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Sensors 封面图
Sensors
IF:
3.5
论文数:
7.2W
被引数:
20.9W

机构

University of California System 封面图
University of California System
学者数:
37.7W
论文数: 33.8W
被引数: 6.6K
引用论文

引用论文

UTE bi-component analysis of T2*relaxation in articular cartilage
err2016-02-01
err53
errOAAI
errShao, H.; Chang, E. Y.; Pauli, C.; Zanganeh, S.; Bae, W.; Chung, C. B.; Tang, G.; Du, J.
err分享
err收藏
Magnetic resonance imaging with ultrashort TE (UTE) PULSE sequences: Technical considerations
err2007-01-26
err217
errOAAI
errTyler, Damian J.; Robson, Matthew D.; Henkelman, R. Mark; Young, Ian R.; Bydder, Graeme M.
err分享
err收藏
Ultrashort echo time spectroscopic imaging (UTESI) of cortical bone
err2007-10-29
err82
errOAAI
errDu, Jiang; Hamilton, Gavin; Takahashi, Atsushi; Bydder, Mark; Chung, Christine B.
err分享
err收藏
Rapid compressed sensing reconstruction of 3D non-Cartesian MRI
err2017-09-23
err61
errOAAI
errBaron, Corey A.; Dwork, Nicholas; Pauly, John M.; Nishimura, Dwight G.
err分享
err收藏
Ultrashort echo time imaging with bicomponent analysis基于双组份分析的超短回波时间成像
err2011-10-27
err101
PREAI
errDu, Jiang; Diaz, Eric; Carl, Michael; Bae, Won; Chung, Christine B.; Bydder, Graeme M.
err分享
err收藏
Design and analysis of a practical 3D cones trajectory
err2006-01-31
err294
errOAAI
errGurney, PT; Hargreaves, BA; Nishimura, DG
err分享
err收藏
学者 查看更多内容