Purpose To characterize the acceleration capabilities of a silent head insert gradient axis that operates at the inaudible frequency of 20 kHz and a maximum gradient amplitude of 40 mT/m without inducing peripheral nerve stimulation. Methods The silent gradient axis' acquisitions feature an oscillating gradient in the phase-encoding direction that is played out on top of a cartesian readout, similarly as done in Wave-CAIPI. The additional spatial encoding fills k-space in readout lanes allowing for the acquisition of fewer phase-encoding steps without increasing aliasing artifacts. Fully sampled 2D gradient echo datasets were acquired both with and without the silent readout. All scans were retrospectively undersampled (acceleration factors R = 1 to 12) to compare conventional SENSE acceleration and acceleration using the silent gradient. The silent gradient amplitude and the readout bandwidth were varied to investigate the effect on artifacts and g-factor. Results The silent readout reduced the g-factor for all acceleration factors when compared to SENSE acceleration. Increasing the silent gradient amplitude from 31.5 mT/m to 40 mT/m at an acceleration factor of 10 yielded a reduction in the average g-factor (g(avg)) from 1.3 +/- 0.14 (g(max) = 1.9) to 1.1 +/- 0.09 (g(max) = 1.6)(.) Furthermore, reducing the number of cycles increased the readout bandwidth and the g-factor that reached g(avg) = 1.5 +/- 0.16 for a readout bandwidth of 651 Hz/pixel and an acceleration factor of R = 8. Conclusion A silent gradient axis enables high acceleration factors up to R = 10 while maintaining a g-factor close to unity (g(avg) = 1.1 and g(max) = 1.6) and can be acquired with clinically relevant readout bandwidths.
Keyword:
acceleration
gradient coil
gradient insert
magnetic resonance imaging
parallel imaging
quiet
silent

期刊

Magnetic Resonance in Medicine 封面图
Magnetic Resonance in Medicine
IF:
3
论文数:
1.2W
被引数:
3.1W

机构

U
Utrecht University
学者数:
6.0W
论文数: 5.1W
被引数: 5.8W
引用论文

引用论文

err分享
err收藏
High slew-rate head-only gradient for improving distortion in echo planar imaging: Preliminary experience
err2016-02-26
err59
errOAAI
errTan, Ek T.; Lee, Seung-Kyun; Weavers, Paul T.; Graziani, Dominic; Piel, Joseph E.; Shu, Yunhong; Huston, John, III; Bernstein, Matt A.; Foo, Thomas K. F.
err分享
err收藏
Silent MRI with soft gradient pulses
err1999-07-01
err126
PREAI
errHennel, F; Girard, F; Loenneker, T
err分享
err收藏
Zigzag sampling for improved parallel imaging改进的并行成像之字形采样
err2008-07-29
err39
errOAAI
errBreuer, Felix A.; Moriguchi, Hisamoto; Seiberlich, Nicole; Blaimer, Martin; Jakob, Peter M.; Duerk, Jeffrey L.; Griswold, Mark A.
err分享
err收藏
Parameter optimization framework on wave gradients of Wave-CAIPI imaging
err2019-10-28
err14
PREAI
errWang, Haifeng; Qiu, Zhilang; Su, Shi; Jia, Sen; Li, Ye; Liu, Xin; Zheng, Hairong; Liang, Dong
err分享
err收藏
err分享
err收藏
Spread-spectrum magnetic resonance imaging
err2019-04-26
err14
PREAI
errScheffler, Klaus; Loktyushin, Alexander; Bause, Jonas; Aghaeifar, Ali; Steffen, Theodor; Schoelkopf, Bernhard
err分享
err收藏
学者 查看更多内容