Accelerating quantitative susceptibility imaging acquisition using compressed sensing

delete2018-12-10
delete19
PRE
AI
N
Nian Wang
G
Gary P. Cofer
R
Robert J. Anderson
Y
Yi Qi
C
Chunlei Liu
G
G. Allan Johnson *
DOI:10.1088/1361-6560/aaf15ddelete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
To evaluate the feasibility of compressed sensing (CS) for accelerating quantitative susceptibility mapping (QSM) acquisition in MR histology, control, demyelination, and remyelination mice were scanned using a modified 3D gradient echo (GRE) pulse sequence (allowing undersampling the k-space in two phase dimensions) at 9.4 T. Fully sampled and CS data at various acceleration factors (AF) (4.0-16.0) were acquired with high spatial resolution of 22.5 mu m(3) isotropic. For prospective scans, the local phase was reconstructed slice-by-slice using a nonlinear reconstruction algorithm with phase cycling, and the QSM was calculated using the iLSQR method. Susceptibility values of major white matter tracts at various CS AF were compared with the fully sampled data as ground truth. The reconstructed QSM preserved major information with negligible artifacts, even at CS AF of 8.0 and 16.0. The maximum variation of susceptibility value of control mice was 5.8% in the fimbria (FI) area with the acceleration factor of 16.0, compared to the ground truth. The maximum variation was 9.5% in corpus callosum (CC) area of the demyelination mouse brain with the acceleration factor of 8.0. The maximum variation was 8.2% in AC area of remyelination mouse brain with 16.0 acceleration factor. This preliminary study shows that CS can reduce the acquisition time of GRE MRI in MR histology without losing significant accuracy in quantitative susceptibility values.
Keyword:
compressed sensing
MR histology
QSM
demyelination
quantitative susceptibility mapping
cuprizone
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Physics in Medicine and Biology 封面图
Physics in Medicine and Biology
IF:
3.4
论文数:
1.4W
被引数:
3.1W

机构

D
Duke University
学者数:
6.3W
论文数: 5.7W
被引数: 6.5W
University of California System 封面图
University of California System
学者数:
37.7W
论文数: 33.8W
被引数: 6.6K
引用论文

引用论文

What we don’t know
err2010-07-06
err0
errOAAI
errWilliam Nazaroff
err分享
err收藏
Compressed sensing for body MRI
err2016-12-16
err254
errOAAI
errFeng, Li; Benkert, Thomas; Block, Kai Tobias; Sodickson, Daniel K.; Otazo, Ricardo; Chandarana, Hersh
err分享
err收藏
Accelerating SENSE Using Compressed Sensing
err2009-09-25
err413
errOAAI
errLiang, Dong; Liu, Bo; Wang, Jiunjie; Ying, Leslie
err分享
err收藏
Layer-specific variation of iron content in cerebral cortex as a source of MRI contrast
err2010-02-23
err346
errOAAI
errFukunaga, Masaki; Li, Tie-Qiang; van Gelderen, Peter; de Zwart, Jacco A.; Shmueli, Karin; Yao, Bing; Lee, Jongho; Maric, Dragan; Aronova, Maria A.; Zhang, Guofeng; Leapman, Richard D.; Schenck, John F.; Merkle, Hellmut; Duyn, Jeff H.
err分享
err收藏
High-field MRI of brain cortical substructure based on signal phase
err2007-07-10
err590
errOAAI
errDuyn, Jeff H.; van Gelderen, Peter; Li, Tie-Qiang; de Zwart, Jacco A.; Koretsky, Alan P.; Fukunaga, Masaki
err分享
err收藏
Compressed sensing in dynamic MRI
err2008-01-28
err554
errOAAI
errGamper, Urs; Boesiger, Peter; Kozerke, Sebastian
err分享
err收藏
err分享
err收藏
学者 查看更多内容