arrow
返回

Accurate convolution/superposition for multi-resolution dose calculation using cumulative tabulated kernels

delete2005-02-03
delete85
PRE
AI
W
Weiguo Lu
G
G Olivera
M
Ming-Li Chen
R
Reckwerdt, PJ
T
T Mackie
DOI:10.1088/0031-9155/50/4/007delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Convolution/superposition (C/S) is regarded as the standard dose calculation method in most modern radiotherapy treatment planning systems. Different implementations of C/S could result in significantly different dose distributions. This paper addresses two major implementation issues associated with collapsed cone C/S: one is how to utilize the tabulated kernels instead of analytical parametrizations and the other is how to deal with voxel size effects. Three methods that utilize the tabulated kernels are presented in this paper. These methods differ in the effective kernels used: the differential kernel (DK), the cumulative kernel (CK) or the cumulative-cumulative kernel (CCK). They result in slightly different computation times but significantly different voxel size effects. Both simulated and real multi-resolution dose calculations are presented. For simulation tests, we use arbitrary kernels and various voxel sizes with a homogeneous phantom, and assume forward energy transportation only. Simulations with voxel size up to 1 cm show that the CCK algorithm has errors within 0.1% of the maximum gold standard dose. Real dose calculations use a heterogeneous slab phantom, both the 'broad' (5 x 5 cm(2)) and the 'narrow' (1.2 x 1.2 cm(2)) tomotherapy beams. Various voxel sizes (0.5 mm, 1 mm, 2 mm, 4 mm and 8 mm) are used for dose calculations. The results show that all three algorithms have negligible difference (0.1%) for the dose calculation in the fine resolution (0.5 mm voxels). But differences become significant when the voxel size increases. As for the DK or CK algorithm in the broad (narrow) beam dose calculation, the dose differences between the 0.5 mm voxels and the voxels up to 8 mm (4 mm) are around 10% (7%) of the maximum dose. As for the broad (narrow) beam dose calculation using the CCK algorithm, the dose differences between the 0.5 mm voxels and the voxels up to 8 mm (4 mm) are around 1% of the maximum dose. Among all three methods, the CCK algorithm is demonstrated to be the most accurate one for multi-resolution dose calculations.
Keyword:
COLLAPSED CONE SUPERPOSITION
ENERGY DEPOSITION KERNELS
PHOTON-BEAM CONVOLUTION
RADIOTHERAPY
TOMOTHERAPY
DELIVERY
MEDIA
MODEL

期刊

Physics in Medicine and Biology 封面图
Physics in Medicine and Biology
IF:
3.4
论文数:
1.4W
被引数:
3.1W

机构

暂无机构信息
引用论文

引用论文

Modified Ridge Analysis
err1979-11-01
err0
PREAI
errA. I. Khuri; Raymond H. Myers
err分享
err收藏
err分享
err收藏
The Topp–Leone odd log-logistic family of distributions
err2017-07-17
err0
PREAI
errE. Brito; G. M. Cordeiro; H. M. Yousof; M. Alizadeh; G. O. Silva
err分享
err收藏
Characterization of Novel Anti-Cathepsin W Antibodies and Cellular Distribution of Cathepsin W in the Gastrointestinal Tract
err2002-01-27
err0
PREAI
errF. Buhling; U. Kellner; D. Guenther; S. Kahl; D. Brömme; E. Weber; P. Malfertheiner; T. Wex
err分享
err收藏
Iterative approaches to dose optimization in tomotherapy
err1999-12-01
err154
PREAI
errShepard, DM; Olivera, GH; Reckwerdt, PJ; Mackie, TR
err分享
err收藏
学者 查看更多内容