Active Power Filter Control With Vibrating Coordinates Transformation
DOI:10.1109/TPWRD.2022.3189782.png)
摘要
En 中文
This paper presents a control system of an active power filter (APF) based on vibrating reference frame transformation. The proposed vibrating reference frame provides a representation of non-sinusoidal quantities (here the active filter current vector) in the form of sinusoidal signals in a stationary frame, and thanks to that, DC signals are achieved in a dq synchronously rotating frame. The article presents theoretical analysis as well as simulation and experimental tests.