arrow
返回

Adaptive diffusion smoothing: A diffusion-based method to reduce IMRT field complexity

delete2008-03-20
delete26
delete
OA
AI
M
M.M. Matuszak *
E
Edward W. Larsen
K
Kyung‐Wook Jee
D
Daniel L. McShan
B
Benedick A. Fraass
DOI:10.1118/1.2889703delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Inverse-planned intensity modulated radiation therapy (IMRT) is often able to achieve complex treatment planning goals that are unattainable with forward three-dimensional (3D) conformal planning. However, the common use of IMRT has introduced several new challenges. The potentially high degree of modulation in IMRT beams risks the loss of some advantages of 3D planning, such as excellent target coverage and high delivery efficiency. Previous attempts to reduce beam complexity by smoothing often result in plan degradation because the smoothing algorithm cannot distinguish between areas of desirable and undesirable modulation. The purpose of this work is to introduce and evaluate adaptive diffusion smoothing (ADS), a novel procedure designed to preferentially reduce IMRT beam complexity. In this method, a discrete diffusion equation is used to smooth IMRT beams using diffusion coefficients, automatically defined for each beamlet, that dictate the degree of smoothing allowed for each beamlet. This yields a method that can distinguish between areas of desirable and undesirable modulation. The ADS method has been incorporated into our optimization system as a weighted cost function penalty, with two diffusion coefficient definitions designed to promote: (1) uniform smoothing everywhere or (2) smoothing based on cost function gradients with respect to the plan beamlet intensities. The ADS method (with both coefficient types) has been tested in a phantom and in two clinical examples (prostate and head/neck). Both types of diffusion coefficients produce plans with reduced modulation and minimal dosimetric impact, but the cost function gradient-based coefficients show more potential for reducing beam modulation without affecting dosimetric plan quality. In summary, adaptive diffusion smoothing is a promising tool for ensuring that only the necessary amount of beam modulation is used, promoting more efficient and accurate IMRT planning, QA, and delivery. (c) 2008 American Association of Physicists in Medicine.
Keyword:
IMRT optimization
beam complexity
diffusion smoothing
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Medical Physics 封面图
Medical Physics
IF:
3.2
论文数:
3.7W
被引数:
3.2W

机构

U
University of Michigan
学者数:
6.4W
论文数: 5.3W
被引数: 124
U
university of michigan system
学者数:
9.1W
论文数: 8.6W
被引数: 133
引用论文

引用论文

Low-intensity exercise training decreases cardiac output and hypertension in spontaneously hypertensive rats
err1997-12-01
err0
PREAI
errAcácio Salvador Véras-Silva; Katt Coelho Mattos; Nilo Sérgio Gava; Patricia Chakur Brum; Carlos Eduardo Negrão; Eduardo Moacyr Krieger
err分享
err收藏
Improving IMRT delivery efficiency using intensity limits during inverse planning
err2005-04-12
err55
errOAAI
errCoselmon, MM; Moran, JM; Radawski, JD; Fraass, BA
err分享
err收藏
Direct aperture optimization: A turnkey solution for step-and-shoot IMRT
err2002-05-13
err345
PREAI
errShepard, DM; Earl, MA; Li, XA; Naqvi, S; Yu, C
err分享
err收藏
Nonlinear anisotropic diffusion filtering of three-dimensional image data from two-photon microscopy
err2004-01-01
err55
errOAAI
errBroser, PJ; Schulte, R; Lang, S; Roth, A; Helmchen, F; Waters, J; Sakmann, B; Wittum, G
err分享
err收藏
err分享
err收藏
Potential new tool for anemia screening: An evaluation of the performance and usability of the TrueHb Hemometer
err2020-03-12
err0
errOAAI
errMegan Parker; Kelsey Barrett; Maria Kahn; Dominira Saul; Pooja Bansil; Charlotte Tawiah; Nicole Advani; Stephanie Zobrist; Tala de los Santos; Emily Gerth-Guyette
err分享
err收藏
err分享
err收藏
学者 查看更多内容