返回
Adaptive Neural Decoder for Prosthetic Hand Control
DOI:10.3389/fnins.2021.590775.png)
摘要
En 中文
The overarching goal was to resolve a major barrier to real-life prosthesis usability-the rapid degradation of prosthesis control systems, which require frequent recalibrations. Specifically, we sought to develop and test a motor decoder that provides (1) highly accurate, real-time movement response, and (2) unprecedented adaptability to dynamic changes in the amputee's biological state, thereby supporting long-term integrity of control performance with few recalibrations. To achieve that, an adaptive motor decoder was designed to auto-switch between algorithms in real-time. The decoder detects the initial aggregate motoneuron spiking activity from the motor pool, then engages the optimal parameter settings for decoding the motoneuron spiking activity in that particular state. Clear-box testing of decoder performance under varied physiological conditions and post-amputation complications was conducted by comparing the movement output of a simulated prosthetic hand as driven by the decoded signal vs. as driven by the actual signal. Pearson's correlation coefficient and Normalized Root Mean Square Error were used to quantify the accuracy of the decoder's output. Our results show that the decoder algorithm extracted the features of the intended movement and drove the simulated prosthetic hand accurately with real-time performance (<10 ms) (Pearson's correlation coefficient >0.98 to >0.99 and Normalized Root Mean Square Error <13-5%). Further, the decoder robustly decoded the spiking activity of multi-speed inputs, inputs generated from reversed motoneuron recruitment, and inputs reflecting substantial biological heterogeneity of motoneuron properties, also in real-time. As the amputee's neuromodulatory state changes throughout the day and the electrical properties and ratio of slower vs. faster motoneurons shift over time post-amputation, the motor decoder presented here adapts to such changes in real-time and is thus expected to greatly enhance and extend the usability of prostheses.
Keyword:
neural decoder
motor decoder
prosthetic hand
motor control
motoneuron modeling
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
IF:
3.2
论文数:
1.6W
被引数:
5.3W
机构
引用论文
Randomized trial of estradiol vaginal ring versus oral oxybutynin for the treatment of overactive bladder雌二醇阴道环与口服奥昔布宁治疗膀胱过度活动症的随机试验
Menopause
IF0
Motor unit drive: a neural interface for real-time upper limb prosthetic control电机单元驱动: 用于实时上肢假肢控制的神经接口
Simulation of ZnO based film bulk acoustic resonator by modified Butterworth-Van Dyke model基于ZnO薄膜体声波谐振器的仿真研究:改进的Butterworth-Van Dyke模型