arrow
返回

Alignment techniques for DRAGON-I LIA

delete2009-08-25
delete2
PRE
AI
Z
Zhiyong Dai *
Y
Yutong Xie
李
李红 (Hong Li)
W
Wenwei Zhang
Y
Yunlong Liu
潘
潘海峰 (Pan Haifeng)
L
Linwen Zhang
D
Deng Jianjun
DOI:10.1088/1674-1137/33/9/016delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
DRAGON-I designed and manufactured by CAEP is a linear induction accelerator which can produce a 20 MeV-3 kA-60 ns electron beam. The high performance required for the machine is determined by the beam quality and thus is greatly dependent on the accelerator alignment. In order to reduce the chromatic effect of the beam, the stretched wire technique has been developed to measure magnetic axes of the cells precisely, and the dipole steering magnets have been equipped into each cell to correct its magnetic axis misalignment. Finally, the laser tracker has been used to examine the installation error of the accelerator. In this paper, different alignment techniques and the primary results are presented and discussed.