arrow
返回

All-solid-state reference electrodes based on conducting polymers

delete2005-01-01
delete91
PRE
AI
A
Anna Kisiel
H
Honorata Marcisz
A
Agata Michalska
K
Krzysztof Maksymiuk
DOI:10.1039/b510868cdelete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
A novel construction of solution free (pseudo) reference electrodes, compatible with all-solid-state potentiometric indicator electrodes, has been proposed. These electrodes use conducting polymers (CP): polypyrrole (PPy) or poly(3,4-ethylenedioxythiophene) (PEDOT). Two different arrangements have been tested: solely based on CP and those where the CP phase is covered with a poly( vinyl chloride) based outer membrane of tailored composition. The former arrangement was designed to suppress or compensate cation- and anion-exchange, using mobile perchlorate ions and poly(4-styrenesulfonate) or dodecylbenzenesulfonate anions as immobilized dopants. The following systems were used: (i) polypyrrole layers doped simultaneously by two kinds of anions, both mobile and immobilized in the polymer layer; (ii) bilayers of polypyrrole with anion exchanging inner layer and cation- exchanging outer layer; (iii) polypyrrole doped by surfactant dodecylbenzenesulfonate ions, which inhibit ion exchange on the polymer/solution interface. For the above systems, recorded potentials have been found to be practically independent of electrolyte concentration. The best results, profound stability of potentials, have been obtained for poly(3,4-ethylenedioxythiophene) or polypyrrole doped by poly(4-styrenesulfonate) anions covered by a poly(vinyl chloride) based membrane, containing both anion- and cation-exchangers as well as solid potassium chloride and silver chloride with metallic silver. Differently to the cases (i)-(iii) these electrodes are much less sensitive to the influence of redox and pH interferences. This arrangement has been also characterized using electrochemical impedance spectroscopy and chronopotentiometry.
Keyword:
MINIATURIZED REFERENCE ELECTRODES
POTENTIOMETRIC MEASUREMENTS
MEMBRANE ELECTRODES
REDOX SENSITIVITY
POLYPYRROLE
SENSORS
BILAYERS
MECHANISM
CONTACT
MATRIX

期刊

A
Analyst
IF:
3.3
论文数:
1.6W
被引数:
3.3W

机构

暂无机构信息
引用论文

引用论文

err分享
err收藏
In vitro verification of doppler prediction of transvalve pressure gradient and orifice area in stenosis
err1984-05-01
err0
PREAI
errJay A. Requarth; Stanley J. Goldberg; Susan Dietrich Vasko; Hugh D. Allen
err分享
err收藏
Topological Crystalline Kondo Insulator in Mixed Valence Ytterbium Borides
err2014-01-07
err0
errOAAI
errHongming Weng; Jianzhou Zhao; Zhijun Wang; Zhong Fang; Xi Dai
err分享
err收藏
Solvent-processible polymer membrane-based liquid junction-free reference electrode
err1998-07-03
err72
PREAI
errLee, HJ; Hong, US; Lee, DK; Shin, JH; Nam, H; Cha, GS
err分享
err收藏
学者 查看更多内容