arrow
返回

Amperometric phenol biosensor based on polyaniline

delete2009-07-01
delete57
PRE
AI
王鹏 封面图
王鹏 (Peng Wang)
刘
刘敏 (Min Liu)
J
Jinqing Kan *
DOI:10.1016/j.snb.2009.05.005delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
The catechol biosensor is constructed by cross-linking between polyphenol oxidase (PPO) and polyaniline (PANI) using glutaraldehyde as a cross-linking agent. The PANI, which is electrochemically synthesized in a solution containing ionic liquid, 1-ethyl-3-methylimidazolium ethyl sulfate, possesses good electroactivity and high conductivity above pH 6. In the presence of catechol as a substrate, the biosensor exhibits a linear range from 0.2 to 80 mu mol dm(-3). The maximum response current (I-max) and the Michaelis-Menten constant (k(m)') are 9.44 mu A and 117 mu mol dm(-3), respectively. The effects of pH and operating potential are also explored to optimize measurement conditions. The activation energy (E-a) of the PPO catalytic reaction is 30.23 kJ mol(-1) in the B-R buffer. Electrochemical impedance spectroscopy (EIS), UV-vis and SEM are used to characterize the PANI-PPO biosensor. The biosensor exhibits good long-term stability. (C) 2009 Elsevier B.V. All rights reserved.
Keyword:
Biosensor
Catechol
Polyphenol oxidase
Polyaniline
Ionic liquid
Cross-linking process
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Sensors and Actuators B-Chemical 封面图
Sensors and Actuators B-Chemical
IF:
7.7
论文数:
3.4W
被引数:
12.6W

机构

Y
Yangzhou University
学者数:
2.8W
论文数: 1.9W
被引数: 3.3W
引用论文

引用论文

Neuropsychology of academic and behavioural limitations in school‐age survivors of bacterial meningitis
err2007-02-13
err0
errOAAI
errIrene Koomen; A Marceline Van Furth; Miriam AC Kraak; Diederick E Grobbee; John J Roord; Aag Jennekens‐Schinkel
err分享
err收藏
A cofactor consumption screen identifies promising NfsB family nitroreductases for dinitrotoluene remediation
err2019-08-07
err0
PREAI
errElsie M. Williams; Abigail V. Sharrock; Elizabeth L. Rylott; Neil C. Bruce; Joanna K. MacKichan; David F. Ackerley
err分享
err收藏
Evaluating the Efficacy and Safety of Internal Cardioversion with Implantable Cardioverter Defibrillator Device for Atrial Fibrillation in Systolic Heart Failure Patients
err2015-06-18
err0
errOAAI
errHamza Sunman; Kudret Aytemir; Hikmet Yorgun; Uğur Canpolat; Muhammet Ulvi Yalçin; Naresh Maharjan; Serkan Asil; Levent Şahiner; Barış Kaya; Necla Özer; Ali Oto
err分享
err收藏
err分享
err收藏
Improved performance of polyaniline-uricase biosensor
err2007-06-01
err91
PREAI
errArora, Kavita; Sumana, G.; Saxena, Vibha; Gupta, R. K.; Gupta, S. K.; Yakhmi, J. V.; Pandey, M. K.; Chand, Subhash; Malhotra, B. D.
err分享
err收藏
学者 查看更多内容