An advanced LAN model based on optimized feature algorithm: Towards hypertension interpretability
DOI:10.1016/j.bspc.2021.102760.png)
摘要
En 中文
Background: The existing cuffless BP measuring methods still show the inadequacy of the model that utilizes long term dependencies in BP dynamics and come up with the outcome of recurrent calibration. Objective: This study aims to develop a learning-based predictive model for continuous BP measurement with long-term evaluation of the cardiovascular parameter. Methods: Towards hypertension interpretability, the proposed model assists the current as well as the previous status of cardiovascular events based on long short-term memory networks (LSTM) and flexible autoregressive integrated moving average (ARIMA). It is often complicated and challenging to continuously estimate BP from random cardiac events. This paper proposes a new SGFA (Sequential Genetic Feature Algorithm) to tackle the feature optimization problem. Results: The experiment was performed on a MIMIC database containing 2780 datafiles of PPG-BP. The proposed model provides the best performance with root mean square error (RMSE) and mean absolute error (MAE) of 1.17 and 1.04 for SBP, whereas 1.06 and 1.02 for DBP. The proposed method has also been evaluated on hypertensive and hypotensive patients. In hypertension condition, estimated SBP and DBP present a good correlation with the true measurements. MAE and RMSE of the estimated SBP are 0.96 and 1.21, whereas, for DBP, it shows 0.42 and 0.57 respectively. Extensive experimentation results confirm that the proposed method delivers a remarkable performance of BP prediction. Conclusion: The proposed work shows a remarkable BP estimation performance compared to the previous inventive methods and signifies insight of various cardiovascular events responsible for BP variation and hypertension interpretability.
Keyword:
AutoRegressive integrated moving average
Blood pressure
Genetic algorithm
Long short-term memory
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
IF:
4.9
论文数:
1.0W
被引数:
2.4W
机构
引用论文
Blood Pressure Estimation Using Photoplethysmogram Signal and Its Morphological Features基于光电容积脉搏波信号的血压估计及其形态学特征
IEEE SENSORS JOURNAL
IF4.5
Long-term and recent trends in hypertension awareness, treatment, and control in 12 high-income countries: an analysis of 123 nationally representative surveys
LANCET
IF88.5
Noninvasive Classification of Blood Pressure Based on Photoplethysmography Signals Using Bidirectional Long Short-Term Memory and Time-Frequency Analysis
IEEE ACCESS
IF3.6