arrow
返回

An algorithm for PET tumor volume and activity quantification: Without specifying camera's point spread function (PSF)

delete2012-06-21
delete9
PRE
AI
R
Ruchir Bhatt *
M
Malek Adjouadi
M
Mohammed Goryawala
S
Seza Güleç
A
Anthony J. McGoron
DOI:10.1118/1.4728219delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Purpose: The authors have developed an algorithm for segmentation and removal of the partial volume effect (PVE) of tumors in positron emission tomography (PET) images. The algorithm accurately measures functional volume (FV) and activity concentration (AC) of tumors independent of the camera's full width half maximum (FWHM). Methods: A novel iterative histogram thresholding (HT) algorithm is developed to segment the tumors in PET images, which have low resolution and suffer from inherent noise in the image. The algorithm is initiated by manually drawing a region of interest (ROI). The segmented tumors are subjected to the iterative deconvolution thresholding segmentation (IDTS) algorithm, where the VanCittert's method of deconvolution is used for correcting PVE. The IDTS algorithm is fully automated and accurately measures the FV and AC, and stops once it reaches convergence. The convergence criteria or stopping conditions are developed in such a way that the algorithm does not rely on estimating the FWHM of the point spread function (PSF) to perform the deconvolution process. The algorithm described here was tested in phantom studies, where hollow spheres (0.5-16 ml) were used to represent tumors with a homogeneous activity distribution, and an irregular shaped volume was used to represent a tumor with a heterogeneous activity distribution. The phantom studies were performed with different signal to background ratios (SBR) and with different acquisition times (1 min, 3 min, and 5 min). The parameters in the algorithm were also changed (FWHM and matrix size of the Gaussian function) to check the accuracy of the algorithm. Simulated data were also used to test the algorithm with tumors having heterogeneous activity distribution. Results: The results show that changing the size and shape of the ROI during initiation of the algorithm had no significant impact on the FV. An average FV overestimation of 30% and an average AC underestimation of 35% were observed for the smallest tumor (0.5 ml) over the entire range of noise and SBR level. The difference in average FV and AC estimations from the actual volumes were less than 5% as the tumor size increased to 16 ml. For tumors with heterogeneous activity profile, the overall volume error was less than 10%. The average overestimation of FV was less than 10% and classification error was around 11%. Conclusions: The algorithm developed herein was extensively tested and is not dependent on accurately quantifying the camera's PSF. This feature demonstrates the robustness of the algorithm and enables it to be applied on a wide range of noise and SBR within an image. The ultimate goal of the algorithm is to be able to be operated independent of the camera type used and the reconstruction algorithm deployed. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4728219]
Keyword:
PET
segmentation
deconvolution
partial volume effect
tumor volume estimation
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Medical Physics 封面图
Medical Physics
IF:
3.2
论文数:
3.7W
被引数:
3.2W

机构

State University System of Florida 封面图
State University System of Florida
学者数:
12.8W
论文数: 10.9W
被引数: 130
F
Florida International University
学者数:
7.4K
论文数: 5.9K
被引数: 1.1W
引用论文

引用论文

Model‐independent depth estimation with the SPI™ method
err2012-03-22
err0
PREAI
errJeffrey B. Thurston; Richard S. Smith; Jean‐Claude Guillon
err分享
err收藏
Lesion quantification in oncological positron emission tomography: A maximum likelihood partial volume correction strategy
err2009-06-10
err16
PREAI
errDe Bernardi, Elisabetta; Faggiano, Elena; Zito, Felicia; Gerundini, Paolo; Baselli, Giuseppe
err分享
err收藏
A novel monoclonal antibody cross-reactive with both human and mouse α9 integrin useful for therapy against rheumatoid arthritis
err2020-05-13
err0
PREAI
errMasaharu Torikai; Hirofumi Higuchi; Nobuchika Yamamoto; Daisuke Ishikawa; Hirotada Fujita; Katsunari Taguchi; Fumihiko Sakai; Kenji Soejima; Toshihiro Nakashima
err分享
err收藏
A novel PET tumor delineation method based on adaptive region-growing and dual-front active contours
err2008-07-18
err110
errOAAI
errLi, Hua; Thorstad, Wade L.; Biehl, Kenneth J.; Laforest, Richard; Su, Yi; Shoghi, Kooresh I.; Donnelly, Eric D.; Low, Daniel A.; Lu, Wei
err分享
err收藏
An iterative technique to segment PET lesions using a Monte Carlo based mathematical model
err2009-09-24
err51
PREAI
errNehmeh, S. A.; El-Zeftawy, H.; Greco, C.; Schwartz, J.; Erdi, Y. E.; Kirov, A.; Schmidtlein, C. R.; Gyau, A. B.; Larson, S. M.; Humm, J. L.
err分享
err收藏
ACCURATE AUTOMATIC DELINEATION OF HETEROGENEOUS FUNCTIONAL VOLUMES IN POSITRON EMISSION TOMOGRAPHY FOR ONCOLOGY APPLICATIONS
err2010-05-01
err159
errOAAI
errHatt, Mathieu; le Rest, Catherine Cheze; Descourt, Patrice; Dekker, Andre; De Ruysscher, Dirk; Oellers, Michel; Lambin, Philippe; Pradier, Olivier; Visvikis, Dimitris
err分享
err收藏
A Fuzzy Locally Adaptive Bayesian Segmentation Approach for Volume Determination in PET
err2009-06-01
err291
errOAAI
errHatt, Mathieu; le Rest, Catherine Cheze; Turzo, Alexandre; Roux, Christian; Visvikis, Dimitris
err分享
err收藏
学者 查看更多内容