返回
An Efficient Autocalibration Method for Triaxial Accelerometer
DOI:10.1109/TIM.2017.2706479.png)
摘要
En 中文
This paper investigates the autocalibration of micro-electromechanical systems (MEMS) triaxial accelerometer (TA) based on experimental design (DoE). First, for a special 6-parameter second-degree model, a six-point experimental scheme is proposed, and its G-optimality has been proven based on optimal DoE. Then, a new linearization approach is introduced, by which the TA model for autocalibration can be simplified as the expected second-degree form so that the proposed optimal experimental scheme can be applied. To reliably estimate the model parameter, a convergence-guaranteed iterative algorithm is also proposed, which can significantly reduce the bias caused by linearization. Thereafter, the effectiveness and robustness of the proposed approach have been demonstrated by simulation. Finally, the proposed calibration method has been experimentally verified using two typical types of MEMS TA, and desired experimental results effectively demonstrate the efficiency and accuracy of the proposed calibration approach.
Keyword:
Calibration
experimental design
model linearization
triaxial accelerometer (TA)
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
IF:
5.9
论文数:
2.0W
被引数:
5.8W
机构
引用论文
Main-chain benzoxazine oligomers: A new approach for resin transfer moldable neat benzoxazines for high performance applications
Polymer
IF0