arrow
返回

An untrained deep learning method for reconstructing dynamic MR images from accelerated model-based data

delete2022-12-05
delete5
delete
OA
AI
K
Kalina P. Slavkova
J
Julie C. DiCarlo
V
Viraj Wadhwa
S
Sidharth Kumar
C
Chengyue Wu
J
John Virostko
T
Thomas E. Yankeelov
J
Jonathan I. Tamir *
DOI:10.1002/mrm.29547delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Purpose To implement physics-based regularization as a stopping condition in tuning an untrained deep neural network for reconstructing MR images from accelerated data. Methods The ConvDecoder (CD) neural network was trained with a physics-based regularization term incorporating the spoiled gradient echo equation that describes variable-flip angle data. Fully-sampled variable-flip angle k-space data were retrospectively accelerated by factors of R = {8, 12, 18, 36} and reconstructed with CD, CD with the proposed regularization (CD + r), locally low-rank (LR) reconstruction, and compressed sensing with L1-wavelet regularization (L1). Final images from CD + r training were evaluated at the argmin of the regularization loss; whereas the CD, LR, and L1 reconstructions were chosen optimally based on ground truth data. The performance measures used were the normalized RMS error, the concordance correlation coefficient, and the structural similarity index. Results The CD + r reconstructions, chosen using the stopping condition, yielded structural similarity indexs that were similar to the CD (p = 0.47) and LR structural similarity indexs (p = 0.95) across R and that were significantly higher than the L1 structural similarity indexs (p = 0.04). The concordance correlation coefficient values for the CD + r T-1 maps across all R and subjects were greater than those corresponding to the L1 (p = 0.15) and LR (p = 0.13) T-1 maps, respectively. For R >= 12 (<= 4.2 min scan time), L1 and LR T-1 maps exhibit a loss of spatially refined details compared to CD + r. Conclusion The use of an untrained neural network together with a physics-based regularization loss shows promise as a measure for determining the optimal stopping point in training without relying on fully-sampled ground truth data.
Keyword:
image reconstruction
inverse problem
physics-guided deep learning
quantitative MRI

期刊

Magnetic Resonance in Medicine 封面图
Magnetic Resonance in Medicine
IF:
3
论文数:
1.2W
被引数:
3.1W

机构

U
university of texas austin
学者数:
2.4W
论文数: 2.0W
被引数: 54
U
university of texas system
学者数:
18.5W
论文数: 15.6W
被引数: 210
引用论文

引用论文

Modified Breastfeeding Attrition Prediction Tool: Prenatal and Postpartum Tests
err2004-01-01
err0
errOAAI
errMarilyn L. Evans; Margaret J. Dick; Lynne P. Lewallen; Cynthia Jeffrey
err分享
err收藏
Five-dimensional quantitative low-dose Multitasking dynamic contrast- enhanced MRI: Preliminary study on breast cancer
err2021-01-11
err7
PREAI
errWang, Nan; Xie, Yibin; Fan, Zhaoyang; Ma, Sen; Saouaf, Rola; Guo, Yu; Shiao, Stephen L.; Christodoulou, Anthony G.; Li, Debiao
err分享
err收藏
CXCL12 Signaling in the Tumor Microenvironment
err2021-07-22
err0
PREAI
errLuigi Portella; Anna Maria Bello; Stefania Scala
err分享
err收藏
RARE: Image Reconstruction Using Deep Priors Learned Without Groundtruth
err2020-10-01
err92
errOAAI
errLiu, Jiaming; Sun, Yu; Eldeniz, Cihat; Gan, Weijie; An, Hongyu; Kamilov, Ulugbek S.
err分享
err收藏
Learning a variational network for reconstruction of accelerated MRI data学习用于重建加速MRI数据的变分网络
err2017-11-08
err1.2K
errOAAI
errHammernik, Kerstin; Klatzer, Teresa; Kobler, Erich; Recht, Michael P.; Sodickson, Daniel K.; Pock, Thomas; Knoll, Florian
err分享
err收藏
Abbreviated MRI of the Breast: Does It Provide Value?
err2018-09-08
err129
errOAAI
errLeithner, Doris; Moy, Linda; Morris, Elizabeth A.; Marino, Maria A.; Helbich, Thomas H.; Pinker, Katja
err分享
err收藏
Alterations in complement-induced shape change and stimulus-specific superoxide anion generation by neonatal calf neutrophils
err1989-12-01
err0
PREAI
errWendy Holden; David O. Slauson; Roland D. Zwahlen; M. Mitsu Suyemoto; Monique Dor�; Nancy R. Neilsen
err分享
err收藏
学者 查看更多内容