arrow
返回

Anatomic and Functional Imaging Using Row-Column Arrays

delete2022-10-01
delete35
delete
OA
AI
J
Jørgen Arendt Jensen *
M
Mikkel Schou
L
Lasse Thurmann Jørgensen
B
Borislav Gueorguiev Tomov
M
Matthias Bo Stuart
M
Marie Sand Traberg
I
Iman Taghavi
S
Sigrid Huesebo Oygaard
M
Martin Lind Ommen
K
Kitty Steenberg
E
Erik Vilain Thomsen
N
Nathalie Sarup Panduro
M
Michael Bachmann Nielsen
C
Charlotte Mehlin Sørensen
DOI:10.1109/TUFFC.2022.3191391delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Row-column (RC) arrays have the potential to yield full 3-D ultrasound imaging with a greatly reduced number of elements compared to fully populated arrays. They, however, have several challenges due to their special geometry. This review article summarizes the current literature for RC imaging and demonstrates that full anatomic and functional imaging can attain a high quality using synthetic aperture (SA) sequences and modified delay-and-sum beamforming. Resolution can approach the diffraction limit with an isotropic resolution of half a wavelength with low sidelobe levels, and the field of view can be expanded by using convex or lensed RC probes. GPU beamforming allows for three orthogonal planes to be beamformed at 30 Hz, providing near real-time imaging ideal for positioning the probe and improving the operator's workflow. Functional imaging is also attainable using transverse oscillation and dedicated SA sequence for tensor velocity imaging for revealing the full 3-D velocity vector as a function of spatial position and time for both blood velocity and tissue motion estimation. Using RC arrays with commercial contrast agents can reveal super-resolution imaging (SRI) with isotropic resolution below 20 mu m. RC arrays can, thus, yield full 3-0 imaging at high resolution, contrast, and volumetric rates for both anatomic and functional imaging with the same number of receive channels as current commercial 1-D arrays.
Keyword:
Beam forming
row-column (RC) arrays
super resolution
ultrasound
velocity measurement

期刊

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control 封面图
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
IF:
3.7
论文数:
6.7K
被引数:
1.4W

机构

U
University of Copenhagen
学者数:
7.6W
论文数: 6.6W
被引数: 86
R
Rigshospitalet
学者数:
1.7W
论文数: 1.3W
被引数: 2.1W
T
technical university of denmark
学者数:
2.6W
论文数: 2.8W
被引数: 37
学者 查看更多机构
引用论文

引用论文

Two-Stage Motion Correction for Super-Resolution Ultrasound Imaging in Human Lower Limb
err2018-05-01
err122
errOAAI
errHarput, Sevan; Christensen-Jeffries, Kirsten; Brown, Jemma; Li, Yuanwei; Williams, Katherine J.; Davies, Alun H.; Eckersley, Robert J.; Dunsby, Christopher; Tang, Meng-Xing
err分享
err收藏
err分享
err收藏
A large aperture row column addressed probe for in vivo 4D ultrafast doppler ultrasound imaging
err2018-10-24
err43
PREAI
errSauvage, J.; Flesch, M.; Ferin, G.; Nguyen-Dinh, A.; Poree, J.; Tanter, M.; Pernot, M.; Deffieux, T.
err分享
err收藏
De-anonymization Attacks on Metaverse
err2023-05-17
err0
PREAI
errYan Meng; Yuxia Zhan; Jiachun Li; Suguo Du; Haojin Zhu; Xuemin Sherman Shen
err分享
err收藏
学者 查看更多内容