arrow
返回

Arbitrary-path fly-scan ptychography

delete2018-05-02
delete36
delete
OA
AI
M
Michal Odstrčil *
M
Mirko Holler
M
Manuel Guizar‐Sicairos
DOI:10.1364/OE.26.012585delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Ptychography is a coherent diffractive imaging method that can provide a diffraction-limited, robust reconstruction of the sample's complex transmission function without the use of high-quality optics. However, the scanning nature of conventional X-ray ptychography unavoidably requires the mechanical motion of either the illumination probe or the sample. In order to avoid overhead related to breaking and acceleration for every scan position, so-called fly-scan methods were developed. Here, we present an improved variant that removes the limitation of continuous scanning along a linear scanning path and allows for ptychographic reconstruction of scans taken along an arbitrary 2D continuous trajectory. We also demonstrate numerically and experimentally that our method provides significantly improved robustness against noise, particularly for larger fly-scan steps, i.e. sample shift during an exposure, which will gain importance with the advent of 4th generation synchrotron sources, where the available coherent flux may be increased by orders of magnitude. Finally, we show that the use of a spiral scan continuous trajectory alleviates significantly raster grid artifacts. (C) 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
Keyword:
COMPUTED-TOMOGRAPHY
RAY
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Optics Express 封面图
Optics Express
IF:
3.3
论文数:
6.1W
被引数:
14.3W

机构

S
swiss federal institutes of technology domain
学者数:
9.0W
论文数: 8.0W
被引数: 163
引用论文

引用论文

Artifact mitigation of ptychography integrated with on-the-fly scanning probe microscopy与即时扫描探针显微镜相结合的ptychography的伪影减轻
err2017-07-11
err25
errOAAI
errHuang, Xiaojing; Yan, Hanfei; Ge, Mingyuan; Ozturk, Hande; Nazaretski, Evgeny; Robinson, Ian K.; Chu, Yong S.
err分享
err收藏
err分享
err收藏
X-ray ptychographic and fluorescence microscopy of frozen-hydrated cells using continuous scanning
err2017-03-27
err54
errOAAI
errDeng, Junjing; Vine, David J.; Chen, Si; Jin, Qiaoling; Nashed, Youssef S. G.; Peterka, Tom; Vogt, Stefan; Jacobsen, Chris
err分享
err收藏
X-ray ptychographic computed tomography at 16 nm isotropic 3D resolution16 nm各向同性3D分辨率的x射线计算机断层扫描
err2014-01-24
err281
errOAAI
errHoller, M.; Diaz, A.; Guizar-Sicairos, M.; Karvinen, P.; Farm, Elina; Harkonen, Emma; Ritala, Mikko; Menzel, A.; Raabe, J.; Bunk, O.
err分享
err收藏
High-throughput ptychography using Eiger: scanning X-ray nano-imaging of extended regions
err2014-06-10
err111
errOAAI
errGuizar-Sicairos, Manuel; Johnson, Ian; Diaz, Ana; Holler, Mirko; Karvinen, Petri; Stadler, Hans-Christian; Dinapoli, Roberto; Bunk, Oliver; Menzel, Andreas
err分享
err收藏
Simultaneous cryo X-ray ptychographic and fluorescence microscopy of green algae绿藻的同时低温x射线照相和荧光显微镜
err2015-02-09
err136
errOAAI
errDeng, Junjing; Vine, David J.; Chen, Si; Nashed, Youssef S. G.; Jin, Qiaoling; Phillips, Nicholas W.; Peterka, Tom; Rossc, Rob; Vogt, Stefan; Jacobsen, Chris J.
err分享
err收藏
学者 查看更多内容