Automatic planning for functional lung avoidance radiotherapy based on function-guided beam angle selection and plan optimization

delete2024-07-17
delete1
delete
OA
AI
T
Tianyu Xiong
G
Guangping Zeng
Z
Zhi Chen
Y
Yuhua Huang
李兵 cover
李兵 (Bing Li)
D
Dejun Zhou
X
Xi Liu
Y
Yang Sheng
G
Ge Ren
H
Hong Ge *
J
Jing Cai *
DOI:10.1088/1361-6560/ad5ef5delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Objective. This study aims to develop a fully automatic planning framework for functional lung avoidance radiotherapy (AP-FLART). Approach. The AP-FLART integrates a dosimetric score-based beam angle selection method and a meta-optimization-based plan optimization method, both of which incorporate lung function information to guide dose redirection from high functional lung (HFL) to low functional lung (LFL). It is applicable to both contour-based FLART (cFLART) and voxel-based FLART (vFLART) optimization options. A cohort of 18 lung cancer patient cases underwent planning-CT and SPECT perfusion scans were collected. AP-FLART was applied to generate conventional RT (ConvRT), cFLART, and vFLART plans for all cases. We compared automatic against manual ConvRT plans as well as automatic ConvRT against FLART plans, to evaluate the effectiveness of AP-FLART. Ablation studies were performed to evaluate the contribution of function-guided beam angle selection and plan optimization to dose redirection. Main results. Automatic ConvRT plans generated by AP-FLART exhibited similar quality compared to manual counterparts. Furthermore, compared to automatic ConvRT plans, HFL mean dose, V-20, and V-5 were significantly reduced by 1.13 Gy (p < .001), 2.01% (p < .001), and 6.66% (p < .001) respectively for cFLART plans. Besides, vFLART plans showed a decrease in lung functionally weighted mean dose by 0.64 Gy (p < .01), fV(20) by 0.90% (p = 0.099), and fV(5) by 5.07% (p < .01) respectively. Though inferior conformity was observed, all dose constraints were well satisfied. The ablation study results indicated that both function-guided beam angle selection and plan optimization significantly contributed to dose redirection. Significance. AP-FLART can effectively redirect doses from HFL to LFL without severely degrading conventional dose metrics, producing high-quality FLART plans. It has the potential to advance the research and clinical application of FLART by providing labor-free, consistent, and high-quality plans.
Keywords:
functional lung avoidance radiotherapy
automatic planning
beam angle selection
plan optimization

Journal

Physics in Medicine and Biology cover
Physics in Medicine and Biology
IF:
3.4
Papers:
1.4W
Citations:
3.1W

Organization

D
Duke University
Scholars:
6.3W
Papers: 5.7W
Citations: 6.5W
H
hong kong polytechnic university
Scholars:
3.0W
Papers: 4.1W
Citations: 921
Z
Zhengzhou University
Scholars:
6.8W
Papers: 4.4W
Citations: 8.5W
researcher View more organizations