BioMEMS device with integrated microdialysis probe and biosensor array

delete2002-10-01
delete29
PRE
AI
P
Petrou, PS
I
I. Moser
G
G. Jobst *
DOI:10.1016/S0956-5663(02)00055-6delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
The fabrication of a microdevice for continuous sampling and on-line monitoring of glucose is described. The device comprised a microdialysis sampling system integrated on the flow through channel of a microfabricated enzyme sensor. The sensor was produced by thin film technology and was assembled to a printed circuit board (PCB) that provided the means for both electrical and fluidic connections. A polyacrilonitrile fibre, with a cut-off of 50 kDa, was used in the fabrication of the sampling probe. The performance of the device was evaluated in-vitro. High sampling efficiency of the microdialysis probe was achieved by appropriate selection of the perfusion fluid flow rate. Response times varying from 1.5 to 3.0 min were determined for flow rates ranging between 1 and 0.2 mul/ min. The linear response range was up to 30 mM glucose and interference from other electroactive substances was almost negligible. The device showed excellent stability under continuous operation for at least 5 days and sensitivity variation less than 3% over a period of 15 days. (C) 2002 Elsevier Science B.V. All rights reserved.
Keyword:
glucose sensor
microdialysis sampling
continuous monitoring
microfabrication
BioMEMS
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Biosensors and Bioelectronics 封面图
Biosensors and Bioelectronics
IF:
10.5
论文数:
1.8W
被引数:
7.7W

机构

暂无机构信息
引用论文

引用论文

err分享
err收藏
err分享
err收藏
Mass producible miniaturized flow through a device with a biosensor array
err1997-09-01
err58
PREAI
errJobst, G; Moser, I; Svasek, P; Varahram, M; Trajanoski, Z; Wach, P; Kotanko, P; Skrabal, F; Urban, G
err分享
err收藏
In vitro optimisation of a microdialysis system with potential for on-line monitoring of lactate and glucose in biological samples
errANALYST
IF3.3
err1997-01-01
err23
PREAI
errDempsey, E; Diamond, D; Smyth, MR; Malone, MA; Rabenstein, K; McShane, A; McKenna, M; Keaveny, TV; Freaney, R
err分享
err收藏
Microdialysis system for continuous glucose monitoring用于连续血糖监测的微透析系统
err1996-07-01
err28
PREAI
errSteinkuhl, R; Sundermeier, C; Hinkers, H; Dumschat, C; Cammann, K; Knoll, M
err分享
err收藏
Wearable microdialysis system for continuous in vivo monitoring of glucose
errANALYST
IF3.3
err1998-01-01
err17
PREAI
errVering, T; Adam, S; Drewer, H; Dumschat, C; Steinkuhl, R; Schulze, A; Siegel, EG; Knoll, M
err分享
err收藏
学者 查看更多内容