arrow
返回

Bootstrap-Optimised Regularised Image Reconstruction for Emission Tomography

delete2020-06-01
delete10
delete
OA
AI
A
Andrew J. Reader *
S
Sam Ellis
DOI:10.1109/TMI.2019.2956878delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
In emission tomography, iterative image reconstruction from noisy measured data usually results in noisy images, and so regularisation is often used to compensate for noise. However, in practice, an appropriate, automatic and precise specification of the strength of regularisation for image reconstruction from a given noisy measured dataset remains unresolved. Existing approaches are either empirical approximations with no guarantee of generalisation, or else are computationally intensive cross-validation methods requiring full reconstructions for a limited set of preselected regularisation strengths. In contrast, we propose a novel methodology embedded within iterative image reconstruction, using one or more bootstrapped replicates of the measured data for precise optimisation of the regularisation. The approach uses a conventional unregularised iterative update of a current image estimate from the noisy measured data, and then also uses the bootstrap replicate to obtain a bootstrap update of the current image estimate. The method then seeks the regularisation hyperparameters which, when applied to the bootstrap update of the image, lead to a best fit of the regularised bootstrap update to the conventional measured data update. This corresponds to estimating the degree of regularisation needed in order to map the noisy update to a model of the mean of an ensemble of noisy updates. For a given regularised objective function (e.g. penalised likelihood), no hyperparameter selection or tuning is required. The method is demonstrated for positron emission tomography (PET) data at different noise levels, and delivers near-optimal reconstructions (in terms of reconstruction error) without any knowledge of the ground truth, nor any form of training data.
Keyword:
Image reconstruction
inverse problems
emission tomography
regularisation
hyperparameter selection
bootstrap methods
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

IEEE Transactions on Medical Imaging 封面图
IEEE Transactions on Medical Imaging
IF:
9.8
论文数:
6.3K
被引数:
3.7W

机构

U
university of london
学者数:
21.5W
论文数: 19.7W
被引数: 305
引用论文

引用论文

err分享
err收藏
4D image reconstruction for emission tomography
err2014-10-31
err100
errOAAI
errReader, Andrew J.; Verhaeghe, Jeroen
err分享
err收藏
Evaluation of Parallel Level Sets and Bowsher's Method as Segmentation- Free Anatomical Priors for Time-of-Flight PET Reconstruction
err2018-02-01
err36
errOAAI
errSchramm, Georg; Holler, Martin; Rezaei, Ahmadreza; Vunckx, Kathleen; Knoll, Florian; Bredies, Kristian; Boada, Fernando; Nuyts, Johan
err分享
err收藏
err分享
err收藏
err分享
err收藏
学者 查看更多内容