arrow
返回

Bragg accelerator optimization

delete2014-07-24
delete12
delete
OA
AI
A
Adi Hanuka *
L
Levi Schächter
DOI:10.1017/hpl.2014.30delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
We present the first steps of a design of the optimal parameters for a full Bragg X-Ray free electron laser (BX-FEL). Aiming towards a future source of coherent X-ray radiation, operating in the strong Compton regime, we envisage the system to be the seed for an advanced light source or compact medical X-ray source. Here we focus on the design of the accelerator parameters: maximum gradient, optimal accelerated charge, maximum efficiency, and 'wake coefficient', which relates to the decelerating electric field generated due to the motion of a charged-line or train of charged-lines. Specifically, we demonstrate that the maximum efficiency has optimal value and given the fluence of the materials, the maximum accelerated charge in the train is constant. These two results might be important in any future design.
Keyword:
Bragg
wake-field
Compton scattering
energy conversion
efficiency
fluence
light source
medical accelerator

期刊

High Power Laser Science and Engineering 封面图
High Power Laser Science and Engineering
IF:
5.7
论文数:
816
被引数:
1.9K

机构

T
Technion Israel Institute of Technology
学者数:
1.6W
论文数: 1.5W
被引数: 2.0W
引用论文

引用论文

err分享
err收藏
High-brightness X-ray free-electron laser with an optical undulator by pulse shaping
err2013-12-17
err23
errOAAI
errChang, Chao; Liang, Jinyang; Hei, Dongwei; Becker, Michael F.; Tang, Kelei; Feng, Yiping; Yakimenko, Vitaly; Pellegrini, Claudio; Wu, Juhao
err分享
err收藏
err
IF0
err
err0
errOAAI
err
err分享
err收藏
Synthesis and Biological Activity of Cyanoethyl Derivatives of Fusidic Acid
err2018-11-08
err0
PREAI
errE. V. Salimova; A. G. Mamaev; E. V. Tret’yakova; O. S. Kukovinets; A. R. Mavzyutov; K. Yu. Shvets; L. V. Parfenova
err分享
err收藏
Beginning to Communicate After Cochlear Implantation
err2003-04-01
err0
PREAI
errDavid J. Ertmer; Lynette M. Strong; Neeraja Sadagopan
err分享
err收藏
Local motion detectors cannot account for the detectability of an extended trajectory in noise
err1999-01-01
err0
PREAI
errPreeti Verghese; Scott N.J Watamaniuk; Suzanne P McKee; Norberto M Grzywacz
err分享
err收藏
Bragg reflection waveguides with a matching layer
err2004-01-01
err49
errOAAI
errMizrahi, A; Schächter, L
err分享
err收藏
Autobiographical memories in women remitted from major depression.
err2000-01-01
err0
PREAI
errHerbert F. Mackinger; Martin M. Pachinger; Max M. Leibetseder; Reinhold R. Fartacek
err分享
err收藏
没有更多内容