CBCT-Based synthetic CT image generation using conditional denoising diffusion probabilistic model

delete2023-08-30
delete29
delete
OA
AI
J
Junbo Peng
R
Richard L. J. Qiu
J
Jacob Wynne
C
Chih‐Wei Chang
S
Shaoyan Pan
T
Tonghe Wang
J
Justin Roper
刘天 封面图
刘天 (Tian Liu)
P
Pretesh Patel
D
David S. Yu
Xiao-Feng Yang 封面图
Xiao-Feng Yang (Xiaofeng Yang) *
DOI:10.1002/mp.16704delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
BackgroundDaily or weekly cone-beam computed tomography (CBCT) scans are commonly used for accurate patient positioning during the image-guided radiotherapy (IGRT) process, making it an ideal option for adaptive radiotherapy (ART) replanning. However, the presence of severe artifacts and inaccurate Hounsfield unit (HU) values prevent its use for quantitative applications such as organ segmentation and dose calculation. To enable the clinical practice of online ART, it is crucial to obtain CBCT scans with a quality comparable to that of a CT scan.PurposeThis work aims to develop a conditional diffusion model to perform image translation from the CBCT to the CT distribution for the image quality improvement of CBCT.MethodsThe proposed method is a conditional denoising diffusion probabilistic model (DDPM) that utilizes a time-embedded U-net architecture with residual and attention blocks to gradually transform the white Gaussian noise sample to the target CT distribution conditioned on the CBCT. The model was trained on deformed planning CT (dpCT) and CBCT image pairs, and its feasibility was verified in brain patient study and head-and-neck (H&N) patient study. The performance of the proposed algorithm was evaluated using mean absolute error (MAE), peak signal-to-noise ratio (PSNR) and normalized cross-correlation (NCC) metrics on generated synthetic CT (sCT) samples. The proposed method was also compared to four other diffusion model-based sCT generation methods.ResultsIn the brain patient study, the MAE, PSNR, and NCC of the generated sCT were 25.99 HU, 30.49 dB, and 0.99, respectively, compared to 40.63 HU, 27.87 dB, and 0.98 of the CBCT images. In the H&N patient study, the metrics were 32.56 HU, 27.65 dB, 0.98 and 38.99 HU, 27.00, 0.98 for sCT and CBCT, respectively. Compared to the other four diffusion models and one Cycle generative adversarial network (Cycle GAN), the proposed method showed superior results in both visual quality and quantitative analysis.ConclusionsThe proposed conditional DDPM method can generate sCT from CBCT with accurate HU numbers and reduced artifacts, enabling accurate CBCT-based organ segmentation and dose calculation for online ART.
Keyword:
CBCT
diffusion model
synthetic CT

期刊

Medical Physics 封面图
Medical Physics
IF:
3.2
论文数:
3.7W
被引数:
3.2W

机构

G
Georgia Institute of Technology
学者数:
1.8W
论文数: 1.4W
被引数: 5.9W
U
university system of georgia
学者数:
7.3W
论文数: 6.6W
被引数: 101
E
Emory University
学者数:
5.0W
论文数: 4.2W
被引数: 5.7W
学者 查看更多机构
引用论文

引用论文

err分享
err收藏
err分享
err收藏
Scatter correction for cone-beam CT in radiation therapy
err2009-05-18
err194
errOAAI
errZhu, Lei; Xie, Yaoqin; Wang, Jing; Xing, Lei
err分享
err收藏
学者 查看更多内容