Cerebral perfusion computed tomography deconvolution via structure tensor total variation regularization

delete2016-04-05
delete28
PRE
AI
D
Dong Zeng
X
Xinyu Zhang
Z
Zhaoying Bian
J
Jing Huang
H
Hua Zhang
L
Lijun Lu
W
Wenbing Lyu
J
Jing Zhang
Q
Qianjin Feng
W
Wufan Chen
J
Jianhua Ma *
DOI:10.1118/1.4944866delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Purpose: Cerebral perfusion computed tomography (PCT) imaging as an accurate and fast acute ischemic stroke examination has been widely used in clinic. Meanwhile, a major drawback of PCT imaging is the high radiation dose due to its dynamic scan protocol. The purpose of this work is to develop a robust perfusion deconvolution approach via structure tensor total variation (STV) regularization (PD-STV) for estimating an accurate residue function in PCT imaging with the low-milliampere-seconds (low-mAs) data acquisition. Methods: Besides modeling the spatio-temporal structure information of PCT data, the STV regularization of the present PD-STV approach can utilize the higher order derivatives of the residue function to enhance denoising performance. To minimize the objective function, the authors propose an effective iterative algorithm with a shrinkage/thresholding scheme. A simulation study on a digital brain perfusion phantom and a clinical study on an old infarction patient were conducted to validate and evaluate the performance of the present PD-STV approach. Results: In the digital phantom study, visual inspection and quantitative metrics (i.e., the normalized mean square error, the peak signal-to-noise ratio, and the universal quality index) assessments demonstrated that the PD-STV approach outperformed other existing approaches in terms of the performance of noise-induced artifacts reduction and accurate perfusion hemodynamic maps (PHM) estimation. In the patient data study, the present PD-STV approach could yield accurate PHM estimation with several noticeable gains over other existing approaches in terms of visual inspection and correlation analysis. Conclusions: This study demonstrated the feasibility and efficacy of the present PD-STV approach in utilizing STV regularization to improve the accuracy of residue function estimation of cerebral PCT imaging in the case of low-mAs. (C) 2016 American Association of Physicists in Medicine.
Keyword:
cerebral perfusion computed tomography
low-mAs
deconvolution
structure tensor total variation
regularization
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Medical Physics 封面图
Medical Physics
IF:
3.2
论文数:
3.7W
被引数:
3.2W

机构

S
southern medical university - china
学者数:
4.6W
论文数: 2.5W
被引数: 50
T
Tianjin Medical University
学者数:
2.4W
论文数: 1.5W
被引数: 1.3W
引用论文

引用论文

A Spatio-Temporal Deconvolution Method to Improve Perfusion CT Quantification一种改进灌注CT量化的时空反卷积方法
err2010-05-01
err31
PREAI
errHe, Lili; Orten, Burkay; Do, Synho; Karl, W. Clem; Kambadakone, Avinish; Sahani, Dushyant V.; Pien, Homer
err分享
err收藏
Sparse angular CT reconstruction using non-local means based iterative-correction POCS
err2011-04-01
err60
PREAI
errHuang, Jing; Ma, Jianhua; Liu, Nan; Zhang, Hua; Bian, Zhaoying; Feng, Yanqiu; Feng, Qianjin; Chen, Wufan
err分享
err收藏
err分享
err收藏
Sparse-view x-ray CT reconstruction via total generalized variation regularization
err2014-05-19
err235
errOAAI
errNiu, Shanzhou; Gao, Yang; Bian, Zhaoying; Huang, Jing; Chen, Wufan; Yu, Gaohang; Liang, Zhengrong; Ma, Jianhua
err分享
err收藏
学者 查看更多内容