Cerebral perfusion computed tomography deconvolution via structure tensor total variation regularization
DOI:10.1118/1.4944866.png)
摘要
En 中文
Purpose: Cerebral perfusion computed tomography (PCT) imaging as an accurate and fast acute ischemic stroke examination has been widely used in clinic. Meanwhile, a major drawback of PCT imaging is the high radiation dose due to its dynamic scan protocol. The purpose of this work is to develop a robust perfusion deconvolution approach via structure tensor total variation (STV) regularization (PD-STV) for estimating an accurate residue function in PCT imaging with the low-milliampere-seconds (low-mAs) data acquisition. Methods: Besides modeling the spatio-temporal structure information of PCT data, the STV regularization of the present PD-STV approach can utilize the higher order derivatives of the residue function to enhance denoising performance. To minimize the objective function, the authors propose an effective iterative algorithm with a shrinkage/thresholding scheme. A simulation study on a digital brain perfusion phantom and a clinical study on an old infarction patient were conducted to validate and evaluate the performance of the present PD-STV approach. Results: In the digital phantom study, visual inspection and quantitative metrics (i.e., the normalized mean square error, the peak signal-to-noise ratio, and the universal quality index) assessments demonstrated that the PD-STV approach outperformed other existing approaches in terms of the performance of noise-induced artifacts reduction and accurate perfusion hemodynamic maps (PHM) estimation. In the patient data study, the present PD-STV approach could yield accurate PHM estimation with several noticeable gains over other existing approaches in terms of visual inspection and correlation analysis. Conclusions: This study demonstrated the feasibility and efficacy of the present PD-STV approach in utilizing STV regularization to improve the accuracy of residue function estimation of cerebral PCT imaging in the case of low-mAs. (C) 2016 American Association of Physicists in Medicine.
Keyword:
cerebral perfusion computed tomography
low-mAs
deconvolution
structure tensor total variation
regularization
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
IF:
3.2
论文数:
3.7W
被引数:
3.2W
机构
引用论文
Simultaneous motion estimation and image reconstruction (SMEIR) for 4D cone-beam CT
MEDICAL PHYSICS
IF3.2
Towards robust deconvolution of low-dose perfusion CT: Sparse perfusion deconvolution using online dictionary learning面向低剂量灌注CT的鲁棒反卷积: 使用在线字典学习的稀疏灌注反卷积
MEDICAL IMAGE ANALYSIS
IF11.8
Stroke Declines From Third to Fourth Leading Cause of Death in the United States Historical Perspective and Challenges Ahead中风从第三位下降到第四位美国的主要死亡原因历史观点和未来的挑战
STROKE
IF8.9