Characterizing a deformable registration algorithm for surface-guided breast radiotherapy

delete2019-12-02
delete10
PRE
AI
J
Juergen Meyer *
W
W. P. Smith
S
Sarah Geneser
B
Brandon Koger
A
Alan M. Kalet
L
Lori Young
N
Ning Cao
R
Ryan Price
C
Chris Norris
T
Tony Horton
J
Jeff Womeldorf
A
Ara Alexandrian
L
Landon S. Wootton
DOI:10.1002/mp.13921delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Purpose Surface-guided radiation therapy (SGRT) is a nonionizing imaging approach for patient setup guidance, intra-fraction monitoring, and automated breath-hold gating of radiation treatments. SGRT employs the premise that the external patient surface correlates to the internal anatomy, to infer the treatment isocenter position at time of treatment delivery. Deformations and posture variations are known to impact the correlation between external and internal anatomy. However, the degree, magnitude, and algorithm dependence of this impact are not intuitive and currently no methods exist to assess this relationship. The primary aim of this work was to develop a framework to investigate and understand how a commercial optical surface imaging system (C-RAD, Uppsala, Sweden), which uses a nonrigid registration algorithm, handles rotations and surface deformations. Methods A workflow consisting of a female torso phantom and software-introduced transformations to the corresponding digital reference surface was developed. To benchmark and validate the approach, known rigid translations and rotations were first applied. Relevant breast radiotherapy deformations related to breast size, hunching/arching back, distended/deflated abdomen, and an irregular surface to mimic a cover sheet over the lower part of the torso were investigated. The difference between rigid and deformed surfaces was evaluated as a function of isocenter location. Results For all introduced rigid body transformations, C-RAD computed isocenter shifts were determined within 1 mm and 1. Additional translational shifts to correct for rotations as a function of isocenter location were determined with the same accuracy. For yaw setup errors, the difference in shift corrections between a plan with an isocenter placed in the center of the breast (BrstIso) and one located 12 cm superiorly (SCFIso) was 2.3 mm/1 in lateral direction. Pitch setup errors resulted in a difference of 2.1 mm/1 in vertical direction. For some of the deformation scenarios, much larger differences up to 16 mm and 7 in the calculated shifts between BrstIso and SCFIso were observed that could lead to large unintended gaps or overlap between adjacent matched fields if uncorrected. Conclusions The methodology developed lends itself well for quality assurance (QA) of SGRT systems. The deformable C-RAD algorithm determined accurate shifts for rigid transformations, and this was independent of isocenter location. For surface deformations, the position of the isocenter had considerable impact on the registration result. It is recommended to avoid off-axis isocenters during treatment planning to optimally utilize the capabilities of the deformable image registration algorithm, especially when multiple isocenters are used with fields that share a field edge.
Keyword:
anatomical deformations
breast radiation therapy
deformable surface registration algorithm
rotational setup errors
surface-guided radiation therapy (SGRT)
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Medical Physics 封面图
Medical Physics
IF:
3.2
论文数:
3.7W
被引数:
3.2W

机构

Seattle Cancer Care Alliance 封面图
Seattle Cancer Care Alliance
学者数:
750
论文数: 635
被引数: 2.2K
U
University of Washington
学者数:
8.0W
论文数: 7.0W
被引数: 12.5W
引用论文

引用论文

BREAST PATIENT SETUP ERROR ASSESSMENT: COMPARISON OF ELECTRONIC PORTAL IMAGE DEVICES AND CONE-BEAM COMPUTED TOMOGRAPHY MATCHING RESULTS
err2010-11-01
err118
PREAI
errTopolnjak, Rajko; Sonke, Jan-Jakob; Nijkamp, Jasper; Rasch, Coen; Minkema, Danny; Remeijer, Peter; van Vliet-Vroegindeweij, Corine
err分享
err收藏
Characterization of a real-time surface image-guided stereotactic positioning system
err2010-09-28
err112
PREAI
errPeng, Jean L.; Kahler, Darren; Li, Jonathan G.; Samant, Sanjiv; Yan, Guanghua; Amdur, Robert; Liu, Chihray
err分享
err收藏
Accuracy of a commercial optical 3D surface imaging system for realignment of patients for radiotherapy of the thorax
err2007-06-06
err115
PREAI
errSchoffel, Philipp J.; Harms, Wolfgang; Sroka-Perez, Gabriele; Schlegel, Wolfgang; Karger, Christian P.
err分享
err收藏
CHANGES PRODUCED IN MUSCLE PROTEINS DURING INCUBATION OF MUSCLE HOMOGENATES
err2006-08-25
err0
PREAI
errKATSUHIRO YAMAMOTO; KUNIHIKO SAMEJIMA; TSUTOMLJ YASUI
err分享
err收藏
Positioning accuracy of cone-beam computed tomography in combination with a hexapod robot treatment table
err2007-03-01
err121
PREAI
errMeyer, Juergen; Wilbert, Juergen; Baier, Kurt; Guckenberger, Matthias; Richter, Anne; Sauer, Otto; Flentje, Michael
err分享
err收藏
Middle Ear Effusion in Children With Congenital Cytomegalovirus Infection
err2020-04-01
err0
errOAAI
errWinnie Chung; Jessica Leung; Tatiana M. Lanzieri; Peggy Blum; Gail Demmler-Harrison
err分享
err收藏
err
IF0
err
err0
PREAI
err
err分享
err收藏
Effect of vitamin D supplementation on thyroid autoimmunity among subjects of autoimmune thyroid disease in a coastal province of India: A randomized open-label trial
err2020-01-01
err0
errOAAI
errKishoreKumar Behera; GautomKumar Saharia; Debasish Hota; DurgeshPrasad Sahoo; Madhusmita Sethy; Anand Srinivasan
err分享
err收藏
Accuracy Evaluation of a 3-Dimensional Surface Imaging System for Guidance in Deep-Inspiration Breath-Hold Radiation Therapy
err2013-02-01
err86
errOAAI
errAlderliesten, Tanja; Sonke, Jan-Jakob; Betgen, Anja; Honnef, Joeri; van Vliet-Vroegindeweij, Corine; Remeijer, Peter
err分享
err收藏
学者 查看更多内容