arrow
返回

Coaxial Waveguide MRI

delete2011-10-21
delete23
delete
OA
AI
S
Stefan Alt
M
Marco Müller *
R
Reiner Umathum
A
A. Bolz
P
Peter Bachert
W
Wolfhard Semmler
M
Michael Bock
DOI:10.1002/mrm.23069delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
As ultrahigh-field MR imaging systems suffer from the standing wave problems of conventional coil designs, the use of antenna systems that generate travelling waves was suggested. As a modification to the original approach, we propose the use of a coaxial waveguide configuration with interrupted inner conductor. This concept can focus the radiofrequency energy to the desired imaging region in the human body and can operate at different Larmor frequencies without hardware modifications, as it is not limited by a lower cut-off frequency. We assessed the potential of the method with a hardware prototype setup that was loaded with a tissue equivalent phantom and operated with imaging areas of different size. Signal and flip angle distributions within the phantom were analyzed, and imaging at different Larmor frequencies was performed. Results were compared to a finite difference time domain simulation of the setup that additionally provides information on the spatial distribution of the specific absorption rate load. Furthermore, simulation results with a human model (virtual family) are presented. It was found that the proposed method can be used for MRI at multiple frequencies, achieving transmission efficiencies similar to other travelling wave approaches but still suffers from several limitations due to the used mode of wave propagation. Magn Reson Med 67:1173-1182, 2012. (c) 2011 Wiley Periodicals, Inc.
Keyword:
MRI
travelling wave MRI
radiofrequency electronics
waveguides
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Magnetic Resonance in Medicine 封面图
Magnetic Resonance in Medicine
IF:
3
论文数:
1.2W
被引数:
3.1W

机构

G
German Cancer Research Center (DKFZ)
学者数:
1.5W
论文数: 1.1W
被引数: 17
H
Helmholtz Association
学者数:
13.2W
论文数: 10.7W
被引数: 145
引用论文

引用论文

Molecular regulations of circadian rhythm and implications for physiology and diseases昼夜节律的分子调控及其对生理和疾病的影响
err2022-02-08
err0
errOAAI
errFrancesca Fagiani; Daniele Di Marino; Alice Romagnoli; Cristina Travelli; Davide Voltan; Lorenzo Di Cesare Mannelli; Marco Racchi; Stefano Govoni; Cristina Lanni
err分享
err收藏
Transmit SENSE
err2002-12-31
err766
errOAAI
errKatscher, U; Börnert, P; Leussler, C; van den Brink, JS
err分享
err收藏
err分享
err收藏
Efficient high-frequency body coil for high-field MRI用于高场MRI的高效高频体线圈
err2004-09-23
err165
errOAAI
errVaughan, JT; Adriany, G; Snyder, CJ; Tian, J; Thiel, T; Bolinger, L; Liu, H; DelaBarre, L; Ugurbil, K
err分享
err收藏
Parallel imaging performance as a function of field strength - An experimental investigation using electrodynamic scaling
err2004-10-26
err171
PREAI
errWiesinger, F; Van De Moortele, PF; Adriany, G; De Zanche, N; Ugurbil, K; Pruessmann, KP
err分享
err收藏
MRI and Localized Proton Spectroscopy in Human Leg Muscle at 7 Tesla Using Longitudinal Traveling Waves
err2010-01-23
err37
errOAAI
errWebb, Andrew G.; Collins, Christopher M.; Versluis, Maarten J.; Kan, Hermien E.; Smith, Nadine B.
err分享
err收藏
学者 查看更多内容