Coronary plaque quantification on energy-integrating and photon-counting detector CT: reproducibility and power modeling for mixed-platform trials

delete2026-07-22
delete0
delete
OA
AI
M
Milan Vecsey-Nagy
M
Muhammad Taha Hagar
J
José Osoria-Velasquez
S
Sardi Hyska
M
Mehmet Gulsun
P
Puneet Sharma
B
Borbála Vattay
B
Bálint Szilveszter
P
Pal Maurovich-Horvat
Á
Ákos Varga‐Szemes *
T
Tilman Emrich
DOI:10.1007/s00330-026-12773-4delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
To evaluate the reproducibility of quantitative plaque characterization between energy-integrating detector (EID)-CT and photon-counting detector (PCD)-CT, identify reconstruction settings yielding the lowest variability, and model sample-size requirements for trial planning. Patients who underwent coronary CT angiography on dual-source EID-CT and PCD-CT within 30 days were screened retrospectively. EID-CT data were reconstructed using quantitative (Qr40) and vascular (Bv40) kernels, while PCD-CT data were reconstructed with Bv36/40/44 and Qr36/40/44 kernels and quantum iterative reconstruction strengths 2–4. For each plaque component (total, low-attenuation, fibrotic, and calcified), volumes were computed using fixed and adaptive Hounsfield-unit thresholds using an automated deep-learning–based plaque-quantification platform and spatially co-registered. Inter-scanner standard deviation (SD) was calculated, and optimal reconstruction pairs were used for power modeling. Thirty-eight patients (age 68.0 [64.0–72.5] years, 30 men) and 77 vessels were included. Inter-scanner correlations were very strong for total (r = 0.85–0.95), fibrotic (r = 0.74–0.94), and calcified plaque (r = 0.92–0.98), and strong for low-attenuation plaque volumes (r = 0.71–0.85). Mean bias ranged from 8.2 to 164.4 mm³ for total plaque volume. Applying the optimal reconstruction pair (Qr40EID-CT vs. Bv36PCD-CT), inter-scanner SDs were 0.14 (vessel-based) and 0.12 (patient-based). At 80% power and α = 0.05, the estimated sample sizes to detect 5% and 10% changes in total plaque volume were 116 and 29 vessels or 92 and 23 patients per group. Quantitative coronary plaque volumes demonstrated high inter-scanner consistency between EID-CT and PCD-CT under optimized conditions. The dual-level power-modeling framework translates inter-scanner variability into actionable sample-size estimates for study design. Question Quantitative coronary plaque volumes are increasingly used as surrogate biomarkers, yet variability between energy-integrating and photon-counting CT remains a major concern. Findings Harmonized reconstruction settings achieved high inter-scanner consistency with low variability when optimized reconstruction settings and automated plaque quantification are applied. Clinical relevance Standardized coronary plaque quantification across CT technologies enables reliable use of quantitative plaque endpoints, supporting mixed-platform longitudinal trials.
Keywords:
Coronary angiography
Computed tomography angiography
Reproducibility of results
Sample size
Biomarker
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

European Radiology cover
European Radiology
IF:
4.7
Papers:
1.6K
Citations:
3.9W

Organization

H
heart and vascular centre
Scholars:
37
Papers: 10
Citations: 0
D
Department of Radiology and Radiological Science
Scholars:
34
Papers: 12
Citations: 0
M
medical imaging centre
Scholars:
33
Papers: 13
Citations: 0
7
755 college road e
Scholars:
3
Papers: 1
Citations: 0
Cited Papers

Cited Papers

Citing Papers

Citing Papers