Optically pumped magnetometer (OPM) array shows a promising future for magnetic source imaging (MSI) in the unshielded Earth's environment, with applications in biomedical imaging and geophysical survey. However, for total-field OPMs in the Mz/Mx mode, radio frequency (RF) magnetic fields oscillating at different frequencies tend to cause crosstalk between adjacent sensors obviously. In this work, a scheme to reduce the RF magnetic field crosstalk between sensor units was investigated. First, the dependence of the Mz magnetometer sensitivity on the RF magnetic field and cell temperature was explored experimentally. To reduce the RF field, we optimized the cell temperature and set lower laser power. With the RF field set to 150 nT, the full-width at half-maximum (FWHM) of the absorption curve of magnetic resonance is 1.12 Hz under 10 mu T, which gives a magnetic resolution of 20 pT. Moreover, three types of coils consisting of the square Helmholtz coils, the biplanar X coils, and the biplanar Z coils have been deeply explored in terms of their stray fields. Compared to the other two kinds of coils, the stray field of biplanar Z coils drops more rapidly in the XOY-plane and the XOZ-plane. Specifically, the minimum spacing between adjacent sensors can be reduced from 23.87 to 10.10 cm if the RF magnetic field is generated by biplanar Z coils instead of the square Helmholtz coils, with crosstalk remaining below 0.1%.
Keyword:
Magnetometers
Coils
Magnetic fields
Radio frequency
Crosstalk
Sensors
Magnetic sensors
Sensitivity
Magnetic resonance
Magnetic resonance imaging
Biplanar coils
crosstalk
optically pumped magnetometer (OPM)

期刊

IEEE Sensors Journal 封面图
IEEE Sensors Journal
IF:
4.5
论文数:
2.2W
被引数:
7.3W

机构

N
Ningbo University
学者数:
2.6W
论文数: 1.8W
被引数: 2.4W
引用论文

引用论文

The particle size effect on some physical properties of neodymium cobaltate-manganites for hydrogen storage use
err2011-01-01
err0
PREAI
errI. A. Abdel-Latif; A. Al-Hajry; H. Hashem; M. H. Ghoza; Th. El-Sherbini; Ali Al-Hajry; Ahmad Umar; Hamoud Al-Harbi; Nadir Bouarissa; Hamid Berriche; Mohammed El-Ghazaly
err分享
err收藏
Compilation of EINECS: Descriptions and definitions used for substances, impurities and mixtures
err1998-01-01
err0
PREAI
errG. Vollmer; K. Rasmussen; G. Christ; O. Nøager; J. B. Davis; A. van der Wielen; C. Haas; A. Fasey
err分享
err收藏
Performance analysis of an optically pumped magnetometer in Earth's magnetic field
err2019-12-12
err15
errOAAI
errOelsner, Gregor; Schultze, Volkmar; IJsselsteijn, Rob; Stolz, Ronny
err分享
err收藏
Precision Magnetometers for Aerospace Applications: A Review用于航空航天应用的精密磁力计: 综述
errSENSORS
IF3.5
err2021-08-18
err59
errOAAI
errBennett, James S.; Vyhnalek, Brian E.; Greenall, Hamish; Bridge, Elizabeth M.; Gotardo, Fernando; Forstner, Stefan; Harris, Glen I.; Miranda, Felix A.; Bowen, Warwick P.
err分享
err收藏
Balanced, bi-planar magnetic field and field gradient coils for field compensation in wearable magnetoencephalography
err2019-10-02
err122
errOAAI
errHolmes, Niall; Tierney, Tim M.; Leggett, James; Boto, Elena; Mellor, Stephanie; Roberts, Gillian; Hill, Ryan M.; Shah, Vishal; Barnes, Gareth R.; Brookes, Matthew J.; Bowtell, Richard
err分享
err收藏
学者 查看更多内容