arrow
返回

CT colonography:: Does improved z resolution help computer-aided polyp detection?

delete2003-09-18
delete8
delete
OA
AI
P
Padmavathi Sundaram
C
Christopher F. Beaulieu
D
David S. Paik
P
Pamela Schraedley-Desmond
S
Sandy Napel
DOI:10.1118/1.1599985delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Multislice helical CT offers several retrospective choices of longitudinal (z) resolution at a given detector collimation setting. We sought to determine the effect of z resolution on the performance of a computer-aided colonic polyp detector, since a human reader and a computer-aided polyp detector may have optimal performances at different z resolutions. We ran a computer-aided polyp detection algorithm on phantom data sets as well as data obtained from a single patient. All data were reconstructed at various slice thicknesses ranging from 1.25 to 10 mm. We studied the performance of the detector at various ranges of polyp sizes using free-response receiver-operating characteristic analyses. We also studied contrast-to-noise ratios (CNR) as a function of slice thickness and polyp size. For the phantom data, reducing the slice thickness from 5 to 1.25 mm improves sensitivity from 84.5% to 98.3% (all polyps), from 61.4% to 95.5% (polyps in the range [0, 5) mm) and from 97.7% to 100% (polyps in the range [5, 10) mm) at a false positive rate of 20 per data set. For polyps larger than 10 mm, there is no significant improvement in detection sensitivity when slice thickness is reduced. CNRs showed expected behavior with slice thickness and polyp size, but in all cases remained high (> 4). The results for the patient data followed similar patterns to that of the phantom case. Thus we conclude that for this detector, the optimal slice thickness is dependent upon the size of the smallest polyps to be detected. For detection of polyps 10 mm and larger, reconstruction of 5 mm sections may be sufficient. Further study is required to generalize these results to a broader population of patients scanned on different scanners. (C) 2003 American Association of Physicists in Medicine.
Keyword:
computer-aided detection
CT colonography
multislice CT
longitudinal resolution
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Medical Physics 封面图
Medical Physics
IF:
3.2
论文数:
3.7W
被引数:
3.2W

机构

暂无机构信息
引用论文

引用论文

Automated polyp detector for CT colonography: Feasibility study
errRADIOLOGY
IF15.2
err2000-07-01
err203
PREAI
errSummers, RM; Beaulieu, CF; Pusanik, LM; Malley, JD; Jeffrey, RB; Glazer, DI; Napel, S
err分享
err收藏
CT colonography: The next colon screening examination?
errRADIOLOGY
IF15.2
err2000-08-01
err209
PREAI
errJohnson, CD; Dachman, AH
err分享
err收藏
err分享
err收藏
Detection of pulmonary metastases with multi-detector row CT scans of 5-mm nominal section thickness: Autopsy lung study
errRADIOLOGY
IF15.2
err2003-01-01
err22
PREAI
errKozuka, T; Johkoh, T; Hamada, S; Naito, H; Tomiyama, N; Koyama, M; Mihara, N; Honda, O; Nakamura, H; Kudo, M
err分享
err收藏
Klinische Formen der Akne
err2005-11-01
err0
PREAI
errT. Jansen; S. Grabbe; G. Plewig
err分享
err收藏
Aqueous solution properties of a poly(vinyl imidazolium sulphobetaine)
err1978-10-01
err0
PREAI
errJ.C. Salamone; W. Volksen; A.P. Olson; S.C. Israel
err分享
err收藏
学者 查看更多内容